What happened

NTSB summary, verbatim

The outboard glass ply failed due to a fracture along the bottom aft edge of the window caused by an electrical arcing event. The arcing event was caused by moisture ingression that came into contact with the window heating terminal block braid wires.

Probable cause

the Board's determination
Moisture ingression thru the window humpseal coming into contact with the terminal block braid wires.

Occurrence sequence

1 stepsNTSB coding · CICTT taxonomy
  1. 1 · Initial climb
    Fire/smoke (non-impact)
    defining event

Findings

2 causal · 1 contributing
  • CAUSE
    Aircraft › Aircraft structures › Windows-windshield system › Flight compartment windows — Incorrect service/maintenance
  • CAUSE
    Personnel issues › Task performance › Maintenance › Scheduled/routine maintenance — Maintenance personnel
  • FACTOR
    Aircraft › Aircraft systems › Ice/rain protection system › Ice/rain prot sys wiring — Malfunction