NTSB ENG20LA043 · Part 121 airline · Class 3

BOMBARDIER INC CL-600-2D24PSA Airlines

Charlotte, NC, USA · 2020-07-24·N561NN

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
Minor
damage

What happened

NTSB summary, verbatim

The arcing/overheating of the braid wire caused the fire event in the cockpit. Removal of the terminal block and sealant revealed an arcing hot spot where the failure occurred at power braid wire position A. There was no visible solder at the connection point of braid wire A, which led to the arcing of the power braid wire and the fire event in the cockpit.

Probable cause

the Board's determination
The windshield failed due to arcing from an inadequate solder connection at the anti-ice power terminal block.

Occurrence sequence

1 stepsNTSB coding · CICTT taxonomy
  1. 1 · Initial climb
    Fire/smoke (non-impact)
    defining event

Findings

1 causal · 0 contributing
  • CAUSE
    Aircraft › Aircraft systems › Ice/rain protection system › Ice/rain prot sys wiring — Failure