FlarePath
NTSB DCA23LA191 · Part 121 airline · Class 4 - Basic report with no Prelim publish

EMBRAER ERJ 190-100 IGWJETBLUE AIRWAYS CORP

New York, NY, USA · 2023-02-25·N337JB

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
Serious injury
highest injury
—
damage

What happened

NTSB summary, verbatim

On February 24, 2023, about 20:30 eastern standard time, an Embraer E190, operated by JetBlue Airways as flight 618 from Minneapolis St. Paul International Airport (MSP), Minneapolis, Minnesota to John F. Kennedy International Airport (JFK), had a ground service agent sustain second degree burns while connecting ground electrical power to the airplane after it blocked into Gate 5, at Terminal 5. According to the ground service agent, after connecting the ground power unit (GPU) he noted that electrical power was not being supplied to the airplane, so he went back to the connection point to confirm that power was on when suddenly the connection between the GPU and the airplane sparked and his right shirt sleeve caught fire and his wrist was burned.

Probable cause

the Board's determination
Electrical sparking caused by a faulty connection between the aircraft and ground power unit resulting in a serious injury to a ground service agent.

Occurrence sequence

1 stepsNTSB coding · CICTT taxonomy
  1. 1 · Standing-engine(s) operating
    Ground handling event
    defining event

Findings

0 causal · 1 contributing
  • FACTOR
    Aircraft › Aircraft systems › Electrical power system › External power system — Malfunction