BOMBARDIER INC CL600-2D24MESABA AVIATION INC
Minneapolis, MN, USA · 2008-04-24·N918XJ
What happened
NTSB summary, verbatimThe flight crew was taxiing the airplane to the runway for departure. The auxiliary power unit had been shut down. The airplane accelerated to cross a runway and was rolling on a taxiway when both engines stopped producing power. The incident flight was part of the captain's initial operating experience as a captain on the CL600. At the time of the incident, the captain had accumulated six hours of total flight time in the CL600. The captain had previously been a pilot on Saab 340 turboprop airplanes. The power lever on the Saab 340 can be moved forward into the ground idle and flight idle positions and rearward into the reverse position. The Saab 340 power lever has a latch that is designed to be lifted to allow the power lever below flight idle. The thrust levers on the CL600 can be moved forward into the idle, climb, takeoff, go-around, and maximum power positions and rearward into the shut off position. The CL600 thrust lever is designed with a latch that has to be lifted to allow movement of the thrust lever into the shut off position. The flight data recorder showed that an application of power occurred about ten seconds from the end of the recording. The recorder shows an engine thrust lever going to the shutoff position near the end of the recording.
Probable cause
the Board's determinationThe flying pilot's incorrect use of the thrust lever leading to the dual engine shutdown during taxi. Contributing to the incident was the flying pilot's lack of total experience in the make and model of airplane.
Occurrence sequence
1 stepsNTSB coding · CICTT taxonomy- 1 · Taxi-to runwayMiscellaneous/otherdefining event
Findings
3 causal · 0 contributing- CAUSEPersonnel issues › Action/decision › Action › Incorrect action performance — Pilot
- CAUSEPersonnel issues › Experience/knowledge › Experience/qualifications › Total experience w/ equipment — Pilot
- CAUSEAircraft › Aircraft power plant › Engine controls › Power lever — Incorrect use/operation
What an account opens
The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.