Fokker F28 MK 0100
Montreal, CA · 2001-03-06·N1426A
What happened
NTSB summary, verbatimThe auxiliary power unit (APU) ingested deicing fluid and snow and sustained an uncontained turbine failure. The pressure bulkhead sustained minor damage. The airplane was being deiced. Four crew and 40 passengers were uninjured. The YUL weather was: Wind 050 degrees at 25 knots gusting to 33 knots; visibility 15 statute miles; present weather drifting snow; sky condition broken 2,800 feet overcast 7,600 feet; temperature -1 degree C; dew point -5 degrees C; altimeter 29.57 inches of mercury. Honeywell's APU teardown inspection stated, "Evidence of an engine overspeed event with a commanded auto-shutdown was present in the Electronic Control Unit (ECU) non-volatile memory." The report further stated, "In February 2001 American Airlines issued a 'Winterization Bulletin' for the F-100 advising that de-ice spray should not be sprayed into the APU inlet. Additionally, the Fokker 100 maintenance manual section 12-31-00, page 301specifically advises 'Do not let de-icing and/or anti-icing fluid/water mixture go into the APU inlet. Injury to persons and/or damage to equipment can occur.'"
Probable cause
the Board's determinationthe inaccurate aircraft deicing service the ground personnel performed alowing fluid injestion and the auxiliary power unit's turbine failure while standing. A factor was the auxiliary power unit's overspeed.
What an account opens
The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.