Boeing 717-200TRANS WORLD AIRLINES
Mascoutah, IL, USA · 2001-08-10·N2417F
What happened
NTSB summary, verbatimThe airplane sustained substantial damage on contact with the runway during an emergency nose gear up landing. Evacuation of the airplane was conducted via the emergency slides. The captain stated, "Repeated radio requests to obtain stairs to deplane were denied due to unavailability. ... Received confirmation that the aircraft was all clear below for engine start and taxi. ... After beginning taxi roll a slight bump was felt that was compatible with a rough ramp area." A passenger stated, "At this point with engines running it seemed that it took a great deal of thrust to get the aircraft moving. I heard the hydraulics when breaks were released, but thought it unusual to use such thrust to get moving on a level ramp without a jet-way. The aircraft was simply pulling straight ahead. There were then two sharp jolts." One of the ground personnel stated, "There was no ground crew free at the time to flag out FLT 519 as I was busy and the other two agents were getting FLT 7637 boarded and it departed at 635P. After flagging out FLT 533 I went over to where FLT 519 had been sitting and discovered the chocks lying on the ramp." NTSB Materials Laboratory report 01-102 on the debris found at Springfield, the spray deflector assembly, and the left hand support assembly stated, "No other piece fractured from the center portion of the deflector assembly. ... Bench binocular microscope examination of the four fractured pieces revealed features typical of overstress separation in a casting. No evidence of a preexisting crack was found on the fractures." Subsequent to the accident, a Boeing Flight Operations Bulletin, dated September 20, 2001, stated, "The purpose of this revision is to clarify and broaden the scope of this operations bulletin, to include possible damage to the NLG SPRAY DEFLECTOR caused by taxiing over a chock, striking a taxiway light or other obstruction, dropping the nosewheel into a pothole, etc. The consequences of such operation may result in damage to the NLG SPRAY DEFLECTOR that may prevent subsequent retraction or extension of the nose gear."
Probable cause
the Board's determinationThe malfunction of the nose gear extension system, which resulted from a previous ground collision with a wheel chock. A factor was the wheel chock.
What an account opens
The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.