Boeing 717-200AIRTRAN AIRWAYS INC
Atlanta, GA, USA · 2004-03-05·N978AT
What happened
NTSB summary, verbatimAccording to the captain, during the climb out from runway 26L at approximately 200 feet, the number 6 display unit on the pilot's instrument panel went blank and the engine alert display left generator off alert displayed. The first officer requested radar vectors from the Atlanta Tower. After contacting the tower the airplane had a complete electrical power failure, and communications with the Atlanta Tower was lost. Emergency electrical power was restored shortly after the electrical failure. The flight attendants advised the captain that there was smoke in the aft part of the cabin area. The captain and first officer "smelled an electrical burning smell", and declared an emergency. The captain returned to the airport and made an emergency landing, and evacuated the airplane on runway 9R. Examination of the Power Conversion Distribution Unit revealed that the tantalum capacitor and the permanent magnet generator input transformer failed. The failed transformer was the apparent source of the smoke in the cabin. No other anomalies were reported by the captain.
Probable cause
the Board's determinationThe failure of the tantalum capacitor and the permanent magnet generator input transformer which resulted in total electrical system failure.