ATSB AO-2025-013 · ATSB (Australia) · Systemic investigation

Bell Helicopter Co 412EPCoulson Aviation (Australia) Pty Ltd

57 km north-east of Strahan Airport, Tasmania · 2025-03-10·VH-VJF

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
Substantial
damage

What happened

ATSB summary, verbatim

Loss of control and equipment contact with water involving Bell 412EP, VH-VJF, 57 km north-east of Strahan Airport, Tasmania, on 10 March 2025 (Collision with terrain, Control issues, Loss of control, Miscellaneous - Other) What happened On 10 March 2025, a Bell 412EP helicopter, registered VH-VJF and operated by Coulson Aviation Australia, was conducting aerial firefighting operations at the Canning Peak fire, about 57 km north-east of Strahan Airport, Tasmania. The helicopter was tasked with firebombing using a longline and bucket in support of ground crews. At about 1525, while filling the third bucket load, the pilot reported the helicopter was in a hover about 150 ft above the water when it unexpectedly sank 50 ft. During the recovery, the pilot was unable to jettison the 150-ft longline (attributed to pressing the ring guard of the electrical release button rather than the centre). The longline became taut, causing the helicopter to come to an abrupt stop accompanied by a loud clunking noise. The pilot then recovered the helicopter to a stable hover above the water, before initiating rearward flight to release the water and retrieve the bucket. Once the bucket and longline were recovered, the pilot climbed to clear the surrounding trees. After clearing the trees, the pilot conducted controllability and engine performance checks and noted that the tail rotor control pedals felt stiff, although they still provided adequate control. The pilot reported a bucket issue and a flight control issue to the interagency air attack supervisor (AAS) via the fire common traffic advisory frequency. The helicopter was then flown back to the Zeehan refuelling base at 65–70 kt. During the return flight, the AAS reported they observed the helicopter yawing from side to side and flying at an unusually low height. The pilot reported that there were no control difficulties apart from the stiff tail rotor control pedals. Upon landing at Zeehan, significant structural damage was discovered to the aft fuselage adjacent to and aft of the external cargo hook, consistent with contact from the longline and bucket system. What the ATSB found The ATSB found that while approaching the dip site, the helicopter entered a steep descent at low forward airspeed and with power applied. These conditions were conducive to the development of an incipient vortex ring state (VRS) and/or settling with power, resulting in an uncommanded descent. During the recovery, the bucket was submerged and the longline remained attached to the helicopter. The resulting loading of the longline led to contact with the helicopter, causing damage to the airframe and flight control systems. The ATSB also found that externally‑mounted cameras and elongated flight steps fitted to the NSW Rural Fire Service (RFS) helicopters reduced pilots’ visibility of the suspended load during bucketing operations. Pilots reported adopting steeper approach profiles to compensate, increasing the helicopter’s susceptibility to aerodynamic conditions associated with settling with power and vortex ring state. In addition, Coulson Aviation Australia’s flight risk assessment tool (FRAT) did not adequately account for mission-specific and aircraft-specific risks associated with aerial firefighting operations. The ATSB identified problems in the design, application and oversight of the FRAT, and found the operator had limited effective mechanisms for improvement of the FRAT. These factors reduced the FRAT’s effectiveness in identifying and managing operational risk. The investigation also identified several factors that increased risk, associated with occurrence reporting processes and the management of pilot recency for specialised aerial firefighting tasks. What has been done as a result Coulson Aviation Australia, in collaboration with the NSW RFS, has enhanced its pilot recency and competency program by providing dedicated Thursday morning recency flight opportunities. The training and checking system has also been revised to require a minimum one-hour external load (bucket operations) recency flight within each 90-day period, supported by enhanced ground-based training incorporating greater technical content on aircraft systems. In addition, Coulson Aviation Australia’s operational risk profile for external load operations has been revised to specifically incorporate VRS and settling with power and degradation of pilot skills as hazards associated with aerial firefighting operations. This ensures these risks are formally identified, assessed and managed through the organisation’s operational risk management framework. Coulson Aviation Australia has commenced a FRAT improvement reform and is progressing to strengthen flight risk management through: • enhanced assurance • a closed-loop risk management process • redesign of the FRAT template to better capture the operational environment and associated operational risks. Coulson Aviation Australia and the NSW RFS have also: • Completed a fleet standardisation review and associated risk assessment for the modification and shortening of all extended left-hand forward flight steps across the Bell 412 fleet. • Started a progressive implementation of a Bell 412 fleet standardisation program to improve commonality of aircraft systems, cockpit layouts, avionics and pilot operating interfaces across the fleet. • Incorporated standardisation modifications into scheduled major maintenance and 5‑year inspection programs. At the time of the response, 2 of the 6 aircraft have completed the full suite of standardisation modifications with a third aircraft currently undergoing modifications. The remaining aircraft will be progressively modified through planned maintenance cycles, with fleetwide implementation scheduled for completion by 2028. • Developed a fortnightly safety meeting aimed at creating greater communication, coordination and accountability over safety between 2 two organisations. Both organisations are also currently: • investigating options for alternative FLIR camera mounting arrangements to determine whether visibility outcomes can be improved while maintaining operational capability requirements • planning to undertake a broader risk assessment examining the relative risks and benefits associated with fixed FLIR installations across the Bell 412 fleet. The Tasmania Fire Service has updated its standard operating procedures to include the immediate reporting of incidents and accidents. In addition, it is currently in the process of implementing reporting workflows for any member within a fireground who witnesses or is a part of an occurrence. Safety message Pilots conducting firefighting operations should remain alert to the operational conditions associated with VRS and settling with power, particularly during approaches to water sources in confined areas where obstacles, reduced recovery options, low airspeeds, and elevated power settings can increase susceptibility to these conditions. Early recognition of developing conditions and timely recovery actions are important, as the cues associated with these phenomena may be subtle or develop rapidly. Operators should ensure that appropriate risk assessment and operational decision‑making tools are available to assist pilots in identifying conditions that may increase exposure to VRS or settling with power during firefighting operations. Risk assessments that consider factors such as confined terrain, aircraft performance, aircraft configuration, environmental conditions, and escape options can assist in maintaining an adequate safety margin throughout the operation.

Findings

the ATSB's findings: contributing factors and other factors that increased risk, verbatim
Findings From the evidence available, the following findings are made with respect to the loss of control and equipment contact with water involving a Bell 412EP, VH-VJF, 57 km north‑east of Strahan Airport, Tasmania, on 10 March 2025. Contributing factors • The pilot conducted a steep approach at a low forward airspeed and high rate of descent, which likely resulted in the helicopter entering an incipient vortex ring state (VRS) and/or settling with power and entering an uncommanded descent. • While focused on the recovery, in the compressed time available, the pilot attempted to, but did not successfully, jettison the bucket and longline. The resulting load on the longline led to contact with the helicopter and damage to the airframe and flight control systems. • Coulson Aviation Australia's flight risk analysis tool (FRAT) did not: - incorporate specific mission risk and aircraft-specific characteristics and performance - fully reflect the operational environment - include clear guidance on the interpretation of certain items . (Safety issue) • Coulson Aviation Australia had limited assurance that the flight risk assessment tool (FRAT) was being used consistently and correctly, and had limited effective mechanisms for improvement of the FRAT and, subsequently, operations. (Safety issue) • NSW Rural Fire Service helicopters operated by Coulson Aviation Australia were routinely configured with external cameras and some had an elongated flight step. During bucketing operations, this impeded the pilot's view and resulted in pilots adopting a steeper approach into a dip site, which increased the helicopter’s susceptibility to settling with power or vortex ring state. (Safety issue) Other factors that increased risk • Following the recovery, the pilot did not jettison the longline and bucket prior to returning to base, increasing the risk of further degradation to the helicopter’s controllability. • Following the occurrence, the pilot did not report the full extent of the event to the air attack supervisor (AAS), resulting in reduced awareness of the circumstances and limiting the opportunity to assess whether the dip area was safe for continued operations. • Coulson Aviation Australia did not immediately submit an incident report directly to the Tasmania Fire Service (TFS), which limited TFS’s ability to assess the safety of the fireground. • Coulson Aviation Australia's procedures for the reporting of incidents and accidents did not require immediate reporting to the authority overseeing the current operation, limiting information available to support effective safety management. • Coulson Aviation Australia pilots were completing the flight risk assessment tool (FRAT) in an inconsistent manner which increased the potential of missions being flown with unidentified and/or unmitigated risk. • The Tasmania Fire Service’s standard operating procedures did not stipulate the immediate reporting of incidents and accidents by pilots or aircraft operators. (Safety issue) • Coulson Aviation Australia did not have requirements to ensure pilots had adequate recency in high skill degradation tasks such as aerial firefighting bucketing operations. (Safety issue)

Safety recommendations

5 issuedwhat changed because of this accident
  • AO-2025-013-SI-01issued

    description: Coulson Aviation Australia did not have requirements to ensure pilots had adequate recency in high skill degradation tasks such as aerial firefighting bucketing operations. Flight risk assessment tool (FRAT) design Safety issue number:

  • AO-2025-013-SI-02issued

    description: Coulson Aviation Australia's flight risk analysis tool (FRAT) did not: - incorporate specific mission risk and aircraft-specific characteristics and performance - fully reflect the operational environment - include clear guidance on the interpretation of certain items. Helicopter configuration Safety issue number:

  • AO-2025-013-SI-03issued

    description: NSW Rural Fire Service (RFS) helicopters operated by Coulson Aviation Australia were routinely configured with external cameras and some had an elongated flight step. During bucketing operations, this impeded the pilot's view and pilots reported adopting a steeper approach into a dip site, which increased the helicopter’s susceptibility to settling with power or vortex ring state (VRS). Managing mission risk Safety issue number:

  • AO-2025-013-SI-04issued

    description: Coulson Aviation Australia had limited assurance that the flight risk assessment tool (FRAT) was being used consistently and correctly, and had limited effective mechanisms for improvement of the FRAT and, subsequently, operations. Reporting procedures to Tasmania Fire Service Safety issue number:

  • AO-2025-013-SI-05issued

    Safety issue description: The Tasmania Fire Service’s standard operating procedures did not stipulate the immediate reporting of incidents and accidents by pilots or aircraft operators. Safety action not associated with an identified safety issue Whether or not the ATSB identifies safety issues in the course of an investigation, relevant organisations may proactively initiate safety action in order to reduce their safety risk. The ATSB has been advised of the following proactive safety action in response to this occurrence. Coulson Aviation Australia’s safety management system (SMS) manual has been updated to strengthen procedural requirements for customer and agency occurrence reporting, including clearer reporting responsibilities, communication pathways and escalation requirements. These enhancements are intended to establish stronger feedback loops between Coulson Aviation Australia and other agencies. Glossary AAS | Air attack supervisor ACO | Air crew officer ADS-B | Automatic dependent surveillance broadcast AFCS | Automatic flight control system AGL | Above ground level AOM | Air operations manager APC | Aerial application rating proficiency check CASA | Civil Aviation Saf