FlarePath
ATSB AO-2021-050 · ATSB (Australia) · Short investigation

De Havilland Canada/De Havilland Aircraft of Canada DHC-8-102Maroomba Airlines

30 km north of Perth Airport, Western Australia · 2021-10-20·VH-QQD

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
—
serious
No injury
highest injury
NONE
damage

What happened

ATSB summary, verbatim

Cabin pressurisation issue involving a De Havilland Canada DHC-8, VH-QQD, 30 km north of Perth Airport, Western Australia, on 20 November 2021 (Air/pressurisation) Executive summary What happened At 0528 on 20 November 2021, a De Havilland Canada DHC-8, registered VH‑QQD, departed on a charter flight from Perth to Port Hedland, Western Australia. As the aircraft approached 10,000 ft, the flight crew carried out transition altitude checklist items and observed that the cabin had not pressurised. The flight crew decided to return to Perth and the aircraft landed uneventfully. What the ATSB found The aircraft had been undergoing maintenance on the day prior to the occurrence, and for operational reasons the recirculation fan had been removed for fitment to another aircraft. VH‑QQD had not been removed from the schedule as the assigned aircraft for the flight, and its unserviceability was not detected prior to flight. The absence of the recirculation fan on the occurrence flight prevented the aircraft from pressurising. The operator’s operations department incorrectly interpreted a message from its engineering department regarding the serviceability status of VH‑QQD, and it remained assigned to the charter flight. This allocation remained on the flight crew’s roster and the flight manifest, which contributed to the flight crew’s confidence that the aircraft was serviceable. As there were no allowable defects against the aircraft, the captain did not check the maintenance log prior to flight and, as a result, did not detect that the recirculation fan had been removed. However, during pre-flight activities the captain observed the circuit breaker that had been opened to facilitate the recirculation fan removal. The captain reset the circuit breaker without reviewing the maintenance log for recent or open defects as per the operator’s flight crew operating manual. What has been done as a result After the occurrence, the operator took the following actions: • refined the terminology used by engineering to communicate aircraft serviceability, and reviewed internal communication methods • distributed an internal memo to all staff advising that if the aircraft technical logs were not located in the crew room when receiving the aircraft, it was to be considered unserviceable • distributed an internal memo to flight crews to reiterate existing paperwork and circuit breaker resetting requirements • incorporated a dedicated compartment for each aircraft’s documents in the crew room with a placard instructing flight crews to contact maintenance watch if the scheduled aircraft’s documents were not in their compartment. Safety message Any task, including those that may seem innocuous, should be performed as though it is the last defence to ensure safe operation. The aircraft documents contain the only reliable records of airworthiness that a pilot should trust, and this occurrence shows that thoroughly checking them remains an important control to determine if the aircraft can be operated.

Findings

the ATSB's findings: contributing factors and other factors that increased risk, verbatim
Findings From the evidence available, the following findings are made with respect to the cabin pressurisation issue involving a De Havilland Canada DHC-8, registered VH‑QQD, 30 km north of Perth Airport, Western Australia, on 20 November 2021. Contributing factors • The flight was commenced without a recirculation fan fitted to the aircraft, preventing the aircraft from pressurising. • When reviewing the aircraft documents prior to accepting the aircraft, and after resetting a circuit breaker, the captain did not check the maintenance log for open entries. As a result, the open entry showing the recirculation fan removal was not detected. • The operations department did not remove the aircraft from its assigned flight after receiving a message from the engineering department about the status of multiple aircraft, including that the assigned aircraft was unserviceable.
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.