Piper Aircraft Corp PA-28AEROPRO PTY LIMITED
Near Bankstown Airport, New South Wales · 2021-03-08·VH-PZG
What happened
ATSB summary, verbatimCarbon monoxide indication during flight involving Piper PA-28, VH-PZG, near Bankstown Airport, New South Wales, on 8 March 2021 (Flight crew incapacitation) What happened On 8 March 2021, the crew of a Piper PA-28 aircraft, registered VH-PZG, were conducting a dual training flight from Bankstown Airport to the Bankstown training area, New South Wales. At the top of climb, at about 4,000 ft near Warragamba Dam, the instructor detected a faint exhaust gas smell and recalled feeling a little more tired than when they took off and mildly lightheaded. The instructor then looked up at the carbon monoxide detector and observed a localised discolouration (indicating the likely presence of carbon monoxide in the cabin). The instructor opened all fresh air vents and windows, and ensured the heater was off. They then advised the student of the positive indication and decided to return to Bankstown. The student continued to fly the aircraft back while the instructor monitored the situation and detector. The aircraft landed safely at Bankstown and the crew were taken to hospital for medical examination. What the ATSB found The ATSB found that the disposable carbon monoxide detector had indicated elevated levels of carbon monoxide in the cabin during the flight. Positive carbon monoxide indications were also reported in two previous flights nine months prior. However, subsequent post-incident inspections and test flights were unable to replicate the conditions nor determine the source of the carbon monoxide. Safety message Carbon monoxide (CO) is a colourless and odourless gas, and its presence may not be detected until the development of physical symptoms and/or cognitive effects. Therefore, operators and owners of piston-engine aircraft are strongly encouraged to install a CO detector with an active warning to alert pilots to the presence of elevated levels of CO in the cabin. Should any smell or sensation of illness develop, pilots should check their CO detector, ensure cabin heat has been turned off, open all fresh air vents and windows, make prompt decisions to land as soon as possible, and use all available resources for assistance. Further information on CO poisoning and detectors can be found at the following: Are you protected from carbon monoxide poisoning? Carbon Monoxide: A Deadly Menace Detection and Prevention of Carbon Monoxide Exposure in General Aviation Aircraft
Findings
the ATSB's findings: contributing factors and other factors that increased risk, verbatimFindings From the evidence available, the following findings are made with respect to the positive carbon monoxide indication involving a Piper PA-28, registered VH-PZG that occurred near Bankstown Airport, New South Wales on 8 March 2021. Other factors that increased risk • The crew were exposed to elevated levels of carbon monoxide in the aircraft cabin.
What an account opens
The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.