Pilatus Aircraft Ltd PC-12/47ERoyal Flying Doctor Service of Australia (Western Operations)
near Albany, Western Australia · 2020-06-22·VH-OWI
What happened
ATSB summary, verbatimUnreliable Airspeed Indication involving Pilatus PC-12/47E, VH-OWI, near Albany, Western Australia, on 22 June 2020 (Avionics/flight instruments) What happened On the evening of 22 June 2020, a Royal Flying Doctor Service, Pilatus Aircraft Ltd. PC-12/47E registered VH‑OWI was conducting a positioning flight from Jandakot to Albany, Western Australia. Approximately four minutes into the descent to Albany Airport in instrument meteorological conditions the pilot observed an airspeed miscompare indication on the left primary flight display (PFD). Having assessed that a blocked pitot tube was the likely cause of the issue, the pilot elected to climb the aircraft in an attempt to get clear of cloud. During this climb the pilot’s indicated airspeed increased and exceeded the aircraft’s maximum allowable speed. The pilot reported also receiving an overspeed alert at this time and consequently elected to discontinue the planned flight and return the aircraft to Jandakot. When unable to obtain visual conditions, the pilot elected to descend the aircraft. During this descent the left indicated airspeed reduced to zero, however, no stall warning was activated. At 6,000 ft visual conditions were obtained, however, the turbulence at this level was severe. At this time the pilot observed a heading miscompare on both the left and right PFDs. Due to the severity of the turbulence at 6,000 ft the pilot climbed the aircraft first to 8,000 ft and then 10,000 ft on the return to Jandakot. The pilot reported that on approach to Jandakot all indications had returned to normal and remained that way until short final when an altitude mismatch and low airspeed warning was identified on the PFDs. What the ATSB found The ATSB determined that during the flight, water entered the aircraft’s pitot tube either as rain or an accumulation of moisture from flying through cloud. Due to a blockage in the pitot tube drain the water had been unable to escape. This in turn obstructed the flow of air to the aircraft’s air data attitude heading reference system, resulting in an incorrect airspeed being displayed on the left PFD and triggering miscompare indications on both PFDs. In addition, a heading miscompare was likely caused by the aircraft’s movement through an area of moderate to severe turbulence during the return to Jandakot. Finally, the ATSB found that recent training that the pilot had undertaken helped them to identify the erroneous airspeed data. Safety message Spurious instrument readings can create a more complex scenario for flight crew than an instrument failure. In this case the pilot’s recent training assisted in effectively assessing the situation, determining the likely failure mode and identifying the most accurate source of available data for a safe return to the departure airport.
Findings
the ATSB's findings: contributing factors and other factors that increased risk, verbatimFindings From the evidence available, the following findings are made with respect to the unreliable airspeed indication involving Pilatus PC-12/47E, VH-OWI which occurred on descent to Albany Airport, Western Australia on 22 June 2020. Contributing factors • Water trapped in the left (pilot’s) side pitot system by a blocked pitot drain likely obstructed the airflow through the pitot lines during the flight. This resulted in inaccurate dynamic air pressure information being received by channel A of the air data attitude heading reference system. • Incorrect air pressure data received by channel A of the air data attitude heading reference system resulted in the calculation and display of false airspeed data on the left primary flight display. This triggered an airspeed miscompare, erroneous alerts and resulted in the pilot returning to Jandakot. Other findings • The heading miscompare detected by the pilot was likely a result of the movement of the aircraft through moderate to severe turbulence.
What an account opens
The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.