FlarePath
ATSB AO-2016-057 · ATSB (Australia) · Occurrence Investigation

Fokker B.V. F28 MK 0100Network Aviation

49 km W of Newman Airport, Western Australia · 2016-06-07·VH-NHF

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
—
serious
No injury
highest injury
NONE
damage

What happened

ATSB summary, verbatim

Depressurisation involving Fokker F28, VH-NHF, 49 km W of Newman Airport, WA on 7 June 2016 (Decompression) What happened On 7 June 2016 at about 1000 Western Standard Time (WST), a Fokker F28 MK 0100 aircraft, registered VH-NHF, departed on a charter flight from Christmas Creek to Perth, Western Australia. On board were five crewmembers and 28 passengers. The aircraft was on climb to the planned cruise altitude of FL 340 [ 1 ] and the weather was generally clear and smooth with intermittent icing conditions. The first officer was the pilot flying (PF) and the captain was the pilot monitoring (PM) for this flight. [ 2 ] As the aircraft climbed through FL 200, the flight crew heard a ‘whistling’ noise. They did not notice any other abnormal indications and after about one minute, the noise stopped. At about FL 305, a loud ‘whooshing’ noise was heard by the flight crew on the flight deck and the three cabin crewmembers who were standing in the forward galley. The cabin crew believed the noise was coming from the forward lavatory, so one cabin crewmember inspected the lavatory, but could not identify where the noise was coming from. The PM checked the aircraft pressurisation indications located on the cockpit overhead panel and noticed that the cabin altitude [ 3 ] indicated 6,000 ft as expected, but the cabin pressure rate of climb had increased from about 200–300 ft/min to about 500 ft/min [ 4 ] (Figure 1). This indicated to the PM that they were losing cabin air faster than the pressurisation system could pressurise the aircraft. Figure 1: F28 cabin pressure gauges Source: Operator annotated by ATSB The PM contacted air traffic control (ATC) to request a level-off at FL 320, rather than their planned level of FL 340. At about this time, the cabin manager informed the flight crew that the cabin crew had heard a ‘suction’ noise from the forward lavatory, but could not identify the source of the noise. The PM asked the cabin manager to cautiously inspect the forward lavatory again. The flight crew then received a ‘PACK 1’ [ 5 ] level 2 warning [ 6 ] in the cockpit and the associated emergency procedure displayed on the multi-function display unit (MFDU). The first step of the procedure was to turn off the affected air-conditioning pack and wait two minutes for the pack to cool before attempting a reset. When the PM turned off air-conditioning pack 1, they noticed the cabin pressurisation rate of climb increase to in excess of 2,000 ft/min. The PM contacted ATC again and requested a descent to FL 250 and received a clearance from ATC to initially descend to FL 290 due to an airspace boundary. Before the PF was able to start the descent, the flight crew received an ‘auto-throttle 1’ [ 7 ] level 1 warning. At about this time, the PM informed the cabin manger that they were about to activate the seat-belt sign because an ‘excessive cabin altitude’ warning was imminent and the emergency oxygen would deploy. Before the two minutes passed for the air-conditioning pack reset, the ‘excessive cabin altitude’ [ 8 ] level 3 warning activated. The flight crew performed their initial drill, [ 9 ] which included donning their oxygen masks. The PM then checked the cabin altitude, noticed it was indicating in excess of 25,000 ft and that the passenger emergency oxygen had deployed, and made a PAN [ 10 ] call to ATC. They received a clearance for an immediate descent to 10,000 ft, and the PF initiated an emergency descent. As the aircraft descended, the cabin crew performed their ‘sit-fit-advise’ [ 11 ] drills for deployment of passenger emergency oxygen and the flight crew performed their ‘emergency descent procedure’. The flight crew completed their ‘excessive cabin altitude’ procedure during the descent and then discussed their requirements for flight at 10,000 ft, which included alternate destination options. The PF levelled the aircraft at 10,000 ft and the flight crew completed the ‘emergency descent procedure’, which included a public address that emergency oxygen was no longer required. The flight crew completed the air-conditioning pack and auto-throttle emergency procedures. After air-conditioning pack 1 was selected on, the cabin altitude decreased to 1,500 ft and the PACK 1 fault did not return for the rest of the flight. The PM left the seat belt light on for the remainder of the flight, but gave permission for the cabin crew to leave their seats to check on the needs of the passengers. The cabin crew checked on the condition of the passengers and noted that one passenger wished to continue using supplemental oxygen. The cabin crew facilitated the passenger’s request and provided them with portable oxygen for the remainder of the flight. ATC contacted the aircraft for a progress update and provided the latest weather details for Newman, Meekatharra and Perth. The flight crew diverted the aircraft to Newman Airport, which was the closest option with company ground services. The crew advised ATC that an ambulance was required on arrival. The aircraft landed at Newman at about 1100. Paramedics were available on arrival at Newman to provide assistance, but were not required. F28 pressurisation – general description Bleed air is compressed air taken from the compressor stage of the engine. Bleed air is used for several functions including pressurisation, air-conditioning and anti-icing. For pressurisation, the bleed air is supplied to the two air-conditioning packs located underneath the floor of the flight deck, which are used to control the temperature of the air prior to distribution into the flight deck and cabin (Figure 2). Cabin pressure is regulated by the outflow valves, which control the outflow of air from the cabin in either automatic or manual mode. Controls for automatic and manual mode of operation are located on the flight deck. In automatic operation, the differential pressure [ 12 ] of 7.46 psi provides a cabin pressure altitude of 8,000 ft at an aircraft altitude of 35,000 ft (FL 350). The outflow valves will normally limit the maximum pressure differential in automatic and manual mode to 7.65 psi and the cabin pressure altitude to 12,000 ft plus or minus 1,500 ft, provided airflow from the air-conditioning pack(s) is available. An excessive cabin altitude warning is presented at 10,000 ft. The cabin is automatically depressurised upon landing and there are two negative pressure relief valves to prevent negative cabin pressure. When one pack is selected off, the respective pack main valve shuts off bleed air supply and the other pack increases its output flow rate to 140 per cent of the normal flow rate. A single pack is capable of maintaining cabin altitude by itself at the maximum operating altitude of FL 350. Air-conditioning pack 1 is located underneath the floor of the flight deck on the left-hand side, which is just forward of the forward lavatory. Figure 2: F28 bleed air supply Source: ATSB Captain (PM) comments The captain provided the following comments: • No systems associated with air-conditioning/pressurisation were recorded as unserviceable before the flight. • The emergency unfolded ‘very quickly’ with multiple faults and therefore knowledge of the emergency drills and procedures needed to be ‘second-nature’. By the time they had performed their initial drills and checked the deployment of the passenger emergency oxygen, the cabin pressure altitude was already indicating in excess of 25,000 ft. • The loud ‘whooshing’ noise was similar to the noise heard in the simulator during rapid decompression training. • They did not feel any physiological effects during the loss of pressure and responded in accordance with their training. • Their simulator training was comprehensive, allowing them to follow procedures while maintaining sufficient ‘spare mental capacity’ to deal with all the problems that unfolded in a logical and methodical manner. Cabin manager comments The cabin manager provided the following comments: • One passenger reported to them there was an unusual smell and the PM indicated to them that this was probably from the fail

Investigation in progress

no final report yet

ATSB has not yet published its conclusions for this accident. FlarePath checks for new material every day; with an account you can follow this investigation and be told when it moves.

In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.