FlarePath
ATSB AO-2015-049 · ATSB (Australia) · Occurrence Investigation

Raytheon Aircraft Company B200

Darwin Airport, NT · 2015-05-17·VH-ZCO

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
—
serious
No injury
highest injury
NONE
damage

What happened

ATSB summary, verbatim

Stall warning event involving a Raytheon B200, VH-ZCO, Darwin Airport, NT on 17 May 2015 Summary On 17 May 2015, the pilot of a Raytheon B200, registered VH-ZCO, was conducting an aeromedical retrieval flight from Darwin, Northern Territory, to Jabiru, also in the Northern Territory. During the take-off, the stall warning horn sounded and the pilot noticed that the aircraft was not performing as well as normally expected. As the initial climb continued, the pilot discovered that the pneumatic boots fitted to the wing leading edges were inflated. The boots are normally held against the contour of the leading edge by a vacuum, and only inflated as required to shed an accumulation of ice. The pilot deduced that the stall warning and relatively poor performance were attributable to the inflated condition of the boots. The pilot also noticed that the aileron control forces were abnormally light. The pilot tried to deflate the boots by cycling the surface de-ice control switch, but to no avail. The pilot elected to return to Darwin and used a higher approach reference speed than normal to provide increased confidence with respect to aircraft controllability and performance. The circuit and landing were uneventful, but the pilot noticed that substantially more power than normal was required to hold the desired speed. The wing de-ice boots remained inflated until the aircraft was parked and the engines were shut down. Subsequent inspection by engineering staff found that the wing de-ice boots inflated during an engine ground run, without having been selected. The boots returned to normal operation when the surface de-ice system control switch was cycled. The pilot had checked the operation of the surface de-ice system prior to the flight, as required by the operator’s pre-flight checklist procedures. Although the system appeared to operate normally, the pilot could not specifically recall confirming that the boots had deflated at the completion of the check, as was normal practise. The pilot believed that the boots probably remained inflated following the check on this occasion, and that the inflated condition went unnoticed. Pilots of Raytheon B200 aircraft, and other aircraft with similar surface de-ice systems, are cautioned that the status of leading edge de-ice boots may not be immediately obvious under some conditions. This incident also serves as a reminder that any aerofoil leading edge contamination, damage or distortion has the potential to significantly adversely affect aircraft performance and handling qualities, and aerodynamic stall characteristics. Aviation Short Investigations Bulletin - Issue 43 What happened At about 1300 Central Standard Time on 17 May 2015, the pilot of a Raytheon B200, registered VH-ZCO, taxied at Darwin Airport for a flight to Jabiru, in the Northern Territory. The flight was an aeromedical retrieval flight, with a doctor and flight nurse on board. The weight of the aircraft was just under the maximum permitted take-off weight. The weather conditions were fine and clear, with a light breeze from the north-east. The pilot positioned the aircraft at the intersection of taxiways U1 and E2 to complete pre-flight run-up checklist procedures. During the first flight of the day, the operator’s run-up checklist procedures included a check to confirm that the wing and horizontal stabiliser de-ice system was serviceable. The wing and horizontal stabiliser de-ice system includes pneumatically inflatable boots fitted to the leading edges of those surfaces (see later description for more detail). The pilot recalled that all run-up checks were normal, including the wing and horizontal stabiliser de-ice system check. Following completion of the run-up checklist procedures, the pilot taxied to the holding point on taxiway E2 before departing from that intersection on runway 11 (Figure 1). Figure 1: Excerpt from Darwin Airport aerodrome chart showing the approximate location where run-up checklist procedures were carried out and the intersection from which the aircraft commenced take-off Source: Airservices Australia, additions by the ATSB The take-off was initiated with the flaps retracted, consistent with the operator’s normal procedures for a take-off under the prevailing conditions. The take-off proceeded normally up to the point that the aircraft reached decision speed [ 1 ] and the pilot rotated the aircraft to the take-off pitch attitude. At that point, the pilot noticed that the aircraft did not ‘unstick’ [ 2 ] as readily as normally expected. At about the same time, the pilot recalled that the stall warning horn sounded. [ 3 ] The pilot continued with the take-off and the aircraft lifted off, but it was not climbing or accelerating as efficiently as normal. Despite the relatively poor performance, the pilot was able to build speed slowly by holding the aircraft in ground effect. [ 4 ] After achieving a positive rate of climb, the pilot retracted the landing gear. As the aircraft continued a shallow climb, the pilot carefully balanced airspeed and rate of climb as the stall warning horn continued to sound intermittently. After passing about 200 ft above ground level, the pilot was able to reduce the pitch attitude to allow the aircraft to accelerate further. Beyond that point, the stall warning horn no longer sounded. Satisfied that the aircraft had reached a safe altitude, the pilot inspected the wings in an attempt to ascertain the reason for the poor take-off performance and stall warning. At that point, the pilot noticed that the right wing de-ice boots appeared to be inflated. Due to the position of the sun, the pilot was unable to immediately ascertain if the boots on the left wing were also inflated. Nonetheless, the pilot was confident that the inflated condition of the wing de-ice boot (or boots) explained the poor performance and stall warning. The pilot immediately cycled the wing and horizontal stabiliser de-ice system control switch in an attempt to deflate the boots, but cycling the switch appeared to have no effect. As the aircraft continued to accelerate, the pilot noticed that aileron control forces were abnormally light. The pilot surmised that light aileron control forces were the result of a disturbance in the airflow over the wing associated with the inflated leading edge de-ice boot (or boots). As the aircraft turned and its orientation changed with respect to the position of the sun, the pilot was able to clearly see that the boots on the left wing were also inflated. The pilot advised air traffic control that a return to Darwin was necessary. Air traffic control initially asked the pilot if runway 36 was acceptable, but uncertain about aircraft performance and noting a crosswind on runway 36, the pilot indicated a preference for runway 11 (runway 11 is substantially longer than runway 36). The pilot was subsequently cleared by air traffic control to make a circuit for runway 11. Given concerns regarding aircraft performance and control, the pilot elected to land with approach flap [ 5 ] selected, and added 20 kt to the approach reference speed. Making the approach at this speed allowed the pilot to comply with the operator’s stabilised approach criteria, while providing increased confidence with respect to aircraft performance and controllability. The pilot had no difficulty handling the aircraft during the circuit and landing, but noted that substantially more power than normal was required to hold the desired speed. The stall warning horn remained silent throughout the approach and landing. The pilot landed without further incident and taxied to the aircraft parking position. The wing de-ice boots remained inflated until the engines were shut down. Subsequent inspection by engineering staff found that the wing de-ice boots inflated again during an engine ground run, without having been selected. The boots returned to normal operation when the wing and horizontal stabiliser de-ice system control switch was cycled. [ 6 ] Numerous subsequent system tests (in accordance with the relevant mai

Investigation in progress

no final report yet

ATSB has not yet published its conclusions for this accident. FlarePath checks for new material every day; with an account you can follow this investigation and be told when it moves.

In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.