FlarePath
ATSB AO-2013-187 · ATSB (Australia) · Occurrence Investigation

PZL Mielec M18A

37 km west of Ulladulla, NSW · 2013-10-24·VH-TZJ

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
—
fatal
—
serious
Fatal
highest injury
Destroyed
damage

What happened

ATSB summary, verbatim

In-flight breakup involving PZL Mielec M18A Dromader aircraft, VH-TZJ, 37 km west of Ulladulla, NSW on 24 October 2013 (In-flight break-up) Summary What happened On 24 October 2013, the pilot of a modified PZL Mielec M18A Dromader, registered VH-TZJ, was conducting a firebombing mission about 37 km west of Ulladulla, New South Wales. On approach to the target point, the left wing separated. The aircraft immediately rolled left and descended, impacting terrain. The aircraft was destroyed and the pilot was fatally injured. What the ATSB found The ATSB found that the left wing separated because it had been weakened by a fatigue crack in the left wing lower attachment fitting. The fatigue crack originated at small corrosion pits in the attachment fitting. These pits formed stress concentrations that accelerated the initiation of fatigue cracks. The ATSB also found that, although required to be removed by the aircraft manufacturer’s instructions, the corrosion pits were not completely removed during previous maintenance. During that maintenance, the wing fittings were inspected using an eddy current inspection method. This inspection method was not approved for that particular inspection and may not have been effective at detecting the crack. Data from a series of previous flights indicated that the manner in which the aircraft was flown during its life probably accelerated the initiation and growth of the fatigue crack. Finally, the ATSB also found a number of other factors which, although they did not contribute to the accident, had potential to reduce the safety of operation of PZL M18 and other aircraft. These included the incorrect calculation of the flight time of M18 aircraft and a lack of robust procedures for the approval of non-destructive inspection procedures. Safety message This accident shows that even when flying within operational limits, the ‘harder’ and faster an aircraft is flown the more rapidly the structure will fatigue. To help ensure that maintenance objectives are consistently met, the ATSB reminds aircraft maintenance personnel of the importance of only using properly-approved maintenance instructions. This accident confirms the importance of referring directly to those maintenance instructions when conducting maintenance. Interim Report released 23 December 2013 On 24 October 2013, at about 0940 Eastern Daylight-saving Time, the pilot of a PZL Mielec M18A Dromader, registered VH-TZJ, took off from Nowra Airport to conduct a firebombing mission in the Budawang National Park about 37 km west of Ulladulla, New South Wales. At about 1004, while the aircraft was approaching the target point, the left wing separated. The aircraft immediately rolled left and descended, impacting terrain. The aircraft was destroyed by impact forces and the pilot was fatally injured. Preliminary examination indicated that the left outboard wing lower attachment lug had fractured through an area of pre-existing fatigue cracking in the lug lower ligament. This Interim Report was released in order to highlight a safety issue that had been identified after the release of the Preliminary Report on 2 December 2013. The safety issue is that operators of some Australian M18 Dromaders, 1 particularly those fitted with turbine engines and enlarged hoppers and those operating under Australian supplemental type certificate (STC) SVA521, have probably conducted flights at weights for which airframe life factoring was required but not applied. The report includes a Safety Advisory Notice to M18 operators about this safety issue. The first sections of this report are the same as the Preliminary Report released on 2 December 2013. Additional information is contained in the Context (Operation of the M18 Dromader at take‑off weights above 4,200 kg), Safety analysis, and Safety action sections regarding the safety issue. 1 There are three main aircraft variants, the M18, M18A, and M18B, in addition to two-seat trainer versions. Throughout this report, ‘M18’ is used generically to refer to any of the three main variants except where otherwise stated. Preliminary Report released 2 December 2013 The ATSB is investigating the fatal aircraft accident involving a PZL-Mielec M18A Dromader, registered VH-TZJ, that occurred near Ulladulla, NSW at about 1004 on 24 October 2013. The aircraft was being used to conduct firebombing operations and while approaching the target point, the left wing separated. The aircraft immediately rolled left and descended, impacting terrain. The aircraft was destroyed by impact forces and the pilot was fatally injured. Preliminary examination indicated that the left outboard wing lower attachment lug had fractured through an area of pre-existing fatigue cracking in the lug lower ligament. Updates The ATSB is investigating the fatal aircraft accident involving a Dromader aircraft that occurred near Ulladulla, NSW on 24 October 2013. The aircraft was being used to conduct aerial work operations when at about 1000 local time, it collided with terrain. The pilot died in the accident. Updated: 1 November 2013 For several days the accident site had been inaccessible due to rugged terrain, high winds, low cloud, and nearby bushfires. On 30 October 2013, due to the efforts of the Rural Fire Service, the NSW National Parks and Wildlife Service, and the NSW Police, a team of five ATSB investigators, including a materials specialist, examined the aircraft wreckage on site (Figure 1). Figure 1: Part of the accident site M18 Dromader aircraft have a cantilever wing; that is, it is anchored at one end with no mid-span supports. The wing consists of three sections; the central wing section, and the left and right outer wing sections (Figure 2). Between each outer wing section and the centre section there are three attachment points. At each of the main spar attachment points, a single lug on the outer wing is secured between two lugs on the centre wing by a through bolt and bush (Figure 3). Figure 2: Overview of wing structure Figure 3: Detail of left wing attachment points (centre wing section not shown) The on-site examination found that the left wing had separated at the joint between the outer wing and the centre wing sections (Figure 4). The ATSB team examined the joints closely to determine the failure mode that resulted in the in-flight separation of the wing. Preliminary examination indicated that the left outer wing lower attachment lug (see arrow in Figure 4 and Figure 5) had fractured through an area of pre-existing fatigue cracking in the lug lower ligament. The fatigue cracking reduced the structural integrity of the fitting to the point where operational loads produced an overstress fracture of the remaining lug material. Figure 4: Outer section of left wing (under side of wing visible) Figure 5: Part of failed attachment lug The ATSB’s on-site examination was completed on 31 October 2013. Several components were removed from the accident site for further examination at the ATSB’s Canberra facilities, including: • both sections of the separated lower main spar lug and the remainder of the lower main spar attachment point (left wing) • the entire upper main spar attachment point (left wing) • part of the rear spar attachment point (left wing) • the entire lower main spar attachment point (right wing). Following M18 Dromader accidents that occurred in the United States involving in-flight wing separation, in September 2000, the United States Federal Aviation Administration issued Airworthiness Directive (AD) 2000‑18-12. This AD required repetitive inspections of the centre wing to outer wing attach joints for ‘cracks in the lugs, corrosion in the main holes, and ovalization of the main holes’. On 19 October 2000, the Australian Civil Aviation Safety Authority (CASA) issued AD/PZL/5 with the same basic inspection requirements. In accordance with AD/PZL/5, inspections were required every 500 hours time in service or every 12 months, whichever came first. The wings of VH-TZJ were last inspected on 8 August 2013. Up to 17 October, the aircraft had accumulated about 110 hours time in servi

Findings

the ATSB's findings: contributing factors and other factors that increased risk, verbatim
Findings From the evidence available, the following findings are made with respect to the in-flight break-up involving modified PZL Mielec M18A Dromader aircraft, registered VH-TZJ, which occurred 37 km west of Ulladulla, New South Wales on 24 October 2013. It should not be read as apportioning blame or liability to any particular organisation or individual.

Safety recommendations

8 issuedwhat changed because of this accident
  • AO-2013-187-SI-01issued

    Who it affects: | Operators of PZL M18 aircraft Status: | Adequately addressed Spectrum of flight loads Operation of M18 aircraft with a more severe flight load spectrum results in greater fatigue damage than anticipated by the manufacturer when determining the service life of the M18. If not properly accounted for, the existing service life limit, and particular inspection intervals, may not provide the intended level of safety. Issue number: |

  • AO-2013-187-SI-02issued

    Who it affects: | Maintainers of M18 aircraft completing CASA AD/PZL/5 and PZL Mielec service bulletin E/02.170/2000 Status: | Safety action pending M18 Dromader airframe life factoring Operators of some Australian M18 Dromaders, particularly those fitted with turbine engines and enlarged hoppers and those operating under Australian supplemental type certificate (STC) SVA521, have probably conducted flights at weights for which airframe life factoring was required but not applied. The result is that some of these aircraft could be close to or have exceeded their prescribed airframe life, increasing the risk of an in-flight failure of the aircraft’s structure. Issue number: |

  • AO-2013-187-SI-03issued

    Who it affects: | All operators of M18 aircraft that have had their M18s inspected using the eddy current procedure QP.00.36 (EC) Status: | Adequately addressed Adequacy of the eddy current inspection procedure The documented procedure for eddy current inspection of M18 wing attachment fittings did not assure repeatable, reliable inspections. Issue number: |

  • AO-2013-187-SI-04issued

    Who it affects: | All operators of M18 aircraft Status: | Adequately addressed Use of eddy current inspection for airworthiness directive AD/PZL/5 The eddy current inspection used on VH-TZJ, and other M18 aircraft, had not been approved by the Civil Aviation Safety Authority as an alternate means of compliance to airworthiness directive AD/PZL/5. This exposed those aircraft to an inspection method that was potentially ineffective at detecting cracks in the wing attachment fittings. Issue number: |

  • AO-2013-187-SI-06issued

    Who it affects: | All operators of M18 aircraft that have had their M18s inspected using eddy current procedure QP.00.36 (EC) Status: | Adequately addressed Civil Aviation Safety Authority records Important information relating to Civil Aviation Safety Authority (CASA) airworthiness directive AD/PZL/5 was not contained in CASA’s airworthiness directive file, but on other CASA files with no cross-referencing between those files. This impacted CASA’s future ability to reliably discover that information and make appropriately‑informed decisions regarding the airworthiness directive. Issue number: |

  • AO-2013-187-SI-07issued

    Who it affects: | All aircraft operators in Australia Status: | Adequately addressed Assessment of NDT procedures The Civil Aviation Safety Authority did not have a defined process for a robust, systematic approach to the assessment and approval of alternative non-destructive inspection procedures to ensure that the proposed method provided an equivalent, or better, level of safety than the original procedure. Issue number: |

  • AO-2013-187-SI-08issued

    Who it affects: | All aircraft operators in Australia Status: | Safety action pending Australian supplemental type certificate SVA521 The engineering justification supporting Australian supplemental type certificate SVA521 did not contain consideration of the effect an increase in the average operating speed could have on the rate of fatigue damage accumulation. Issue number: |

  • AO-2013-187-SI-09issued

    Who it affects: | All aircraft operators of the M18 aircraft in Australia operating under STC SVA521 Status: | Adequately addressed General details Date: | 24 Oct 2013 | | Investigation status: | Completed | Time: | 1004 EDT | | Investigation type: | Occurrence Investigation | Location ( show map ) : | 37 km west of Ulladulla | | Occurrence type: | In-flight break-up | State: | NSW | | Occurrence class: | Operational | Release date: | 15 Feb 2016 | | Occurrence category: | Accident | Report status: | Final | | Highest injury level: | Fatal | Aircraft details Aircraft manufacturer: | PZL Mielec | Aircraft model: | M18A | Aircraft registration: | VH-TZJ | Serial number: | 1Z013-32 | Type of operation: | Aerial Work | Sector: | Turboprop | Damage to aircraft: | Destroyed |

In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.