Kavanagh Balloons E-260
near Alice Springs Airport, NT · 2013-07-13·VH-FSR
What happened
ATSB summary, verbatimFlight preparation event involving Kavanagh Balloons E-260, VH-FSR, near Alice Springs Airport, NT, 13 July 2013 (Aircraft preparation) What happened On the morning of 13 July 2013 a Kavanagh E-260 balloon, registered VH-FSR, was being prepared for a charter tourist flight near Alice Springs, Northern Territory. Due to the wind conditions at the time, the passengers were pre-loaded into the balloon basket as it lay on its side. As one of the passengers prepared to enter the basket, their scarf became entangled in a fan that was being used to inflate the balloon envelope. Consequently, the passenger was rapidly drawn into contact with the fan’s steel guard and the scarf was pulled tightly around their neck. Despite being provided with first aid, and subsequent medical treatment, the passenger died as a result of their injuries several days later. What the ATSB found The ATSB found that pre-loading of the passengers during the inflation process, although appropriate in the wind conditions, resulted in them coming into close proximity to the operating inflation fan. Additionally, the mesh and steel tubing guard positioned around the inflation fan was ineffective in preventing loose items of clothing from becoming entangled in the wooden fan blades and driveshaft. As a result, when the passenger approached the balloon basket in preparation for loading, their scarf was drawn into the fan blades, leading to fatal injuries. The pilot conducted two safety briefings prior to the proposed flight that advised the passengers to remain clear of the fan as it was noisy and dangerous. A warning sign fitted to the fan was also pointed out. However, none of the passengers recalled that the specific danger of fan entanglement had been mentioned. Safety message This accident highlights how quickly entanglement in industrial equipment, such as the inflation fan, can cause fatal injury. While highlighting the danger to those unfamiliar can reduce the risk, isolating the hazard through effective fan safeguarding and passenger control is the most effective method of preventing such tragic accidents. On 13 July 2013 at about 0530 Central Standard Time [ 1 ] a bus containing 10 passengers, a balloon pilot and a driver/ground crew member departed from Alice Springs, Northern Territory for a location on the outskirts of the city. The bus was ferrying the passengers and crew to the launch site of a charter flight in a Kavanagh E-260 balloon, registered VH-FSR. A large trailer, containing the balloon and required launch equipment was towed behind the bus. As the bus travelled toward the planned departure site, the balloon pilot provided the passengers with a safety briefing that highlighted some of the hazards involved with the flight. That briefing included the requirement for the passengers to remain clear of the fan used to inflate the balloon (see the section titled Cold- air inflation fan ). On arrival at the planned launch site the balloon crew assessed that the location was unsuitable as the prevailing wind would have carried the balloon towards power lines during departure. Consequently, the crew decided to move to another location about 2 km away. Once at the alternative launch site, the wind speed for the departure was found to be greater than ideal. The pilot reported that, as the wind often dropped at around sunrise, it was decided to wait until that time to launch the balloon. On that day sunrise occurred at about 0717. During the wait the pilot conducted a further passenger briefing that reiterated how the flight was to progress as well as the hazards. Specifically, the passengers were told: • to remain clear of the cold-air inflation fan • that they were not permitted between the balloon basket and the bus during inflation. The requirement to remain clear of the area between the basket and the bus was to minimise the risk of injury should the balloon basket move during inflation. Additionally, as the basket was tethered to the front of the bus during the inflation process, there was also a trip hazard associated with the tether. The passengers were also informed that, due to the wind, they would be pre-loaded into the basket while it was positioned on its side and before the balloon was fully inflated (see the section titled Passenger loading procedure ). The passengers were divided into two groups of five and allocated their positions in the basket. Due to the basket configuration, with the pilot and gas bottles occupying the centre area, passenger loading was only possible from either end of the basket (Figure 1). Figure 1: Balloon basket passenger and pilot compartments Source: ATSB Following assessment that the wind speed was within the allowable limits, the balloon inflation process commenced at about 0700 using the cold-air inflation fan. Two of the passengers assisted with the inflation, under the supervision of the crew, by supporting the balloon’s mouth (Figure 2). Figure 2: Passengers assisting with the initial balloon inflation Source: C and J Siviour As the balloon inflated the ground crew member repositioned to take control of a long rope (crown line) that was attached to the top of the balloon envelope (Figure 3). The crown line ensured that the balloon envelope remained stable as it inflated and did not contact the basket, burner or inflation fan. Operation of the crown line resulted in the ground crew member being over 50 m away from the basket and out of sight of the pilot and passengers. The pilot remained at the basket to conduct preflight checks on the balloon and supervise the loading of the passengers. Figure 3: Example of a ground crew member controlling the balloon crown line Source: ATSB Once the balloon was inflated sufficiently for the balloon mouth to support itself, the assisting passengers moved to their allocated end of the basket ready for loading. Once they were clear of the mouth, the pilot accelerated the inflation process by using the burners positioned on the frame mounted above the basket to heat and expand the air within the envelope (Figure 4). Figure 4: Balloon inflation was assisted by the application of burner heat once the assisting passengers had moved clear of the balloon mouth Source: C and J Siviour As the balloon envelope inflated it gradually rotated to the left and aligned itself with the wind. As a result of that movement, the basket connected to the balloon was pulled around closer to the inflation fan (Figures 5 and 6). In response, the pilot repositioned the fan away from the basket a number of times to ensure continued efficient inflation of the balloon. Figure 5: Balloon basket originally positioned parallel to the front of the bus Source: C and J Siviour Figure 6: The basket orientation altered as the balloon increased in size and became affected by the wind Source: R Bernoth At around 0715, the pilot instructed the passengers allocated basket positions furthest from the inflation fan to commence pre-loading (Figure 7). After several of the passengers had entered the basket, the pilot directed the passengers assigned locations closest to the fan to begin preloading. The pilot reported that he monitored the passengers as they entered both ends of the basket. During the loading process he remained on the fan-side of the basket near to the balloon’s burner frame, about 1.5 m to 2 m away from the fan. The passenger’s recollection of the distance between the basket and the fan varied between 1 and 2.5 m. Figure 7: Passengers pre-loading into the side of the basket furthest from the inflation fan (Note: the pilot on the left side adjusting the fan’s position) Source: N Poulsen The first passenger who entered the basket on the fan-side stated that they gained access by moving through a gap between the fan and the basket as they did not wish to be subjected to the force of the air that would have resulted from passing in front of the fan. Several passengers situated close to the fan recalled that a second passenger then similarly moved between the fan and the basket to begin preloading. In contrast, the pilot recalled that both passengers appro
Findings
the ATSB's findings: contributing factors and other factors that increased risk, verbatimContributing factors • Pre-loading of the passengers during the inflation process, although appropriate in the wind conditions, resulted in them coming into close proximity to the operating cold-air inflation fan. • The mesh and steel tubing guard positioned around the cold-air inflation fan was ineffective in preventing loose items of clothing from becoming entangled in the wooden fan blades and driveshaft. • In preparation for loading, the passenger moved sufficiently close to the operating cold-air inflation fan for their scarf to be drawn into the fan blades, leading to their fatal injuries. No safety issues were identified during this investigation. However, the following proactive safety action was taken by a number of organisations in response to this occurrence.
Safety recommendations
1 issuedwhat changed because of this accident- AO-2013-116-SI-01issued
Who it affects: | Balloon operators General details Date: | 13 Jul 2013 | | Investigation status: | Completed | Time: | 0720 CST | | Investigation type: | Occurrence Investigation | Location ( show map ) : | near Alice Springs Airport | | Occurrence type: | Aircraft preparation | State: | NT | | Occurrence class: | Operational | Release date: | 09 Dec 2015 | | Occurrence category: | Accident | Report status: | Final | | Highest injury level: | Fatal | Aircraft details Aircraft manufacturer: | Kavanagh Balloons | Aircraft model: | E-260 | Aircraft registration: | VH-FSR | Serial number: | E260-403 | Type of operation: | Charter | Sector: | Balloon | Damage to aircraft: | Nil | Departure point: | near Alice Springs, NT
What an account opens
The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.