FlarePath
ATSB AO-2008-056 · ATSB (Australia) · Occurrence Investigation

Embraer-Empresa Brasileira De Aeronautica ERJ 170

Melbourne Airport 90deg M/22km, VIC · 2008-08-10·VH-ZHA

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
—
serious
No injury
highest injury
NONE
damage

What happened

ATSB summary, verbatim

Flight control system event, 22km east of Melbourne Airport, VIC, 10 August 2008, VH-ZHA, Embraer ERJ170-100 (Flight control systems) Summary On 10 August 2008, an Embraer-Empresa Brasileira De Aeronautica ERJ170-100 aircraft, registered VH-ZHA, was being operated on a scheduled passenger service from Sydney NSW, to Melbourne Vic. While positioning for landing, the crew selected a 'flaps 1' setting and a number of caution messages appeared on the engine indicating and crew alerting system (EICAS) screen. The aircraft operator found that the left number-3 slat actuator torque trip limiter had actuated enabling the caution messages to appear on the EICAS screen. The number-3 slat actuator was replaced. A strip and condition report did not identify any failure of the actuator and the failure was probably a result of operating in icing conditions. As a result of similar occurrences, the slat actuator manufacturer is re-designing the slat actuator seals.

Findings

the ATSB's findings: contributing factors and other factors that increased risk, verbatim
Findings From the evidence available, the following findings are made with respect to the flight control system event involving the Embraer-Empresa Brasileira De Aeronautica ERJ170-100 aircraft registered VH-ZHA. These findings should not be read as apportioning blame or liability to any particular organisation or individual. Contributing safety factors • The failure of the number-3 slat actuator to extend imposed landing limitations on the aircraft. • It is probable that the failure of the number-3 slat actuator to extend was the result of extremely cold conditions [Safety Issue]. Other key findings • Activation of the slat actuator torque trip prevented asymmetric extension of the slats.
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.