The Boeing Company 747
CULIN NSW, 270 degrees/93 km, NSW · 2008-02-25·VH-EBY
What happened
ATSB summary, verbatimFumes Event, VH-EBY, 275 km WSW of Sydney, NSW, 25 Feb 2008 Summary On 25 February 2008, at about 2128 Eastern Daylight-saving Time, the flight crew of a Boeing Company 747-338 (747) aircraft, registered VH-EBY, detected a smell that slowly increased in intensity. At that time, the aircraft was cruising at 37,000 ft and was about 275 km west south-west of Sydney, NSW. The flight crew donned their emergency oxygen equipment and transmitted a PAN call to air traffic control. The aircraft was cleared direct to Sydney for landing and was escorted to the terminal by the airport fire services for disembarkation. An inspection by the operator determined that loose terminal connections to the left windshield heat element resulted in electrical arcing and fumes on the flight deck. The aircraft manufacturer has a programme to replace the windshields in the 747 with an enhanced windshield heater wiring connection that should address the risk of electrical arcing in that component.
Findings
the ATSB's findings: contributing factors and other factors that increased risk, verbatimFindings From the evidence available, the following findings are made with respect to the fumes event involving Boeing Company 747-338 aircraft, registration VH-EBY that occurred 275 km west- south-west of Sydney, NSW on 25 February 2008. They should not be read as apportioning blame or liability to any particular organisation or individual. Contributing safety factors • The loose terminal connections to the left windshield increased the electrical resistance and resulted in electrical arcing and fumes on the flight deck. Other safety factors • The pilot in command’s intercommunication (ICS) was inadvertently disconnected when the flight crew donned their emergency oxygen equipment. Other key findings • The potential for the recent maintenance in the vicinity of the left windshield/crash pad to have contributed to the insecurity of the left windshield terminal connections could not be determined. • The redesign of the windshield by the manufacturer to improve the security of the windshield heater wiring connection should address the risk of electrical arcing in that component.
What an account opens
The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.