The Boeing Company 747
25 km NNW of Bangkok International Airport, International · 2008-01-07·VH-OJM
What happened
ATSB summary, verbatimElectrical system event - Boeing 747-438, VH-OJM, 25 km NNW of Bangkok International Airport, Thailand, 7 January 2008 Summary On 7 January 2008, a Boeing Company 747-438 aircraft, registered VH-OJM, was being operated on a scheduled international regular public transport service between London, England and Bangkok, Thailand. The aircraft had 346 passengers and 19 crew on board, including four flight crew. On descent to Bangkok International Airport, the customer service manager notified the flight crew that a substantial water leak had occurred in the forward galley. The cockpit indications progressively showed a number of electrical power-related malfunctions, and many of the aircraft's communication, navigation, monitoring and flight guidance systems were affected. A number of flight and navigation display and other instruments were available in degraded mode and the standby instruments and instrument landing system were also available. The aircraft's engines and hydraulic and pneumatic systems were largely unaffected and an approach was made to Bangkok in day visual meteorological conditions. The investigation found the galley leak was from an overflowing drain after a drain line had been blocked with ice that formed due to an inoperable drain line heater. The water flowed forward and through a decompression panel into the aircraft's main equipment centre before leaking onto three of the aircraft's four generator control units, causing them to malfunction and shut down. The investigation identified a number of safety issues in regard to the protection of aircraft systems from liquids, and other factors including the provision of information to flight crews. In response, the aircraft manufacturer and operator implemented a number of safety actions intended to prevent a recurrence. In addition, the United States Federal Aviation Administration issued a notice of proposed rulemaking to adopt a new airworthiness directive for certain 747-400 and 747-400D series aircraft to install improved water protection. The Australian Transport Safety Bureau has issued two safety recommendations and one safety advisory notice as a result of the investigation.
Findings
the ATSB's findings: contributing factors and other factors that increased risk, verbatimFindings From the evidence available, the following findings are made with respect to the electrical systems event that occurred 25 km north-north-west of Bangkok International Airport, Thailand on 7 January 2008 and involved Boeing Company 747-438 aircraft, registered VH-OJM, and should not be read as apportioning blame or liability to any particular organisation or individual. 3.1 Contributing safety factors • Electrical power to the aircraft’s alternating and direct current buses 1, 2, and 3 and associated electrical equipment was lost during the flight after generator control units 1, 2, and 3 malfunctioned as a result of past and present waste water ingress. • Waste water leaked through a decompression panel in the cabin floor, then through dripshields and into electrical equipment after the forward drain line was blocked with ice that formed due to an inoperable drain line heater. • Maintenance processes did not identify or correct the: – deterioration of the dripshield [Significant safety issue] – corrosion in the generator control units [Minor safety issue] – inoperability of the forward drain line heater. [Significant safety issue] • The location of the decompression panel and absence of cabin floor sealing above the main equipment centre increased the risk of liquid ingress into the aircraft’s electrical systems. [Significant safety issue] 3.2 Other safety factors • The galley drain operation and maintenance processes did not adequately prevent blockage and overflow of the aircraft’s drain lines. [Minor safety issue] • The aircraft operator’s forward drain mast modification increased the risk of a blockage in the aircraft’s forward drain lines. • The floor sealing around the forward galley was not of sufficient extent to prevent liquids from passing through to the under floor area. [Minor safety issue] • Maintenance processes did not identify or correct the deterioration of the galley floor sealing. [Minor safety issue] • The aircraft operator’s documented design objectives did not explicitly require the protection of non-structural systems from liquid contact or ingress. [Minor safety issue] • The United States Federal Aviation Administration regulations and associated guidance material did not fully address the potential harm to flight safety posed by liquid contamination of electrical system units in transport category aircraft. [Significant safety issue] - 71 - • The priority level of the battery discharge messages that were provided by the engine indicating and crew alerting system did not accurately reflect the risk presented by the battery discharge status. [Significant safety issue] • The flight crew quick reference handbook did not include sufficient information for the flight crew to appropriately manage operations on standby power. [Significant safety issue] • The flight crew did not declare the aircraft’s situation to air traffic control or to the cabin crew, which would have enabled them to more effectively prepare for and manage any adverse change in the aircraft’s situation. • The flight crew did not review the aircraft status prior to taxiing to the terminal. - 72 -
Safety recommendations
11 issuedwhat changed because of this accident- AO-2008-003-SI-01issued
Who it affects: | Operators of Boeing 747-400 aircraft Status: | Partially addressed Floor sealing design The location of the decompression panel and absence of cabin floor sealing above the main equipment centre increased the risk of liquid ingress into the aircraft’s electrical systems. Issue number: |
- AO-2008-003-SI-02issued
Who it affects: | Operators of Boeing 747-400 aircraft Status: | Partially addressed Maintenance processes for corrosion in the generator control units Maintenance processes did not identify or correct the corrosion in the generator control units. Issue number: |
- AO-2008-003-SI-03issued
Who it affects: | Operators of aircraft fitted with Hamilton Sundstrand Corporation generator or bus control units Status: | Adequately addressed Maintenance processes for drain line heater Maintenance processes did not identify or correct the inoperability of the forward drain line heater. Issue number: |
- AO-2008-003-SI-04issued
Who it affects: | Operators of Boeing 747-400 aircraft Status: | Adequately addressed Maintenance processes for galley floor sealing Maintenance processes did not identify or correct the deterioration of the galley floor sealing Issue number: |
- AO-2008-003-SI-05issued
Who it affects: | Operators of Boeing 747-400 aircraft Status: | Adequately addressed Maintenance for drain lines The galley drain operation and maintenance processes did not adequately prevent blockage and overflow of the aircraft’s drain lines. Issue number: |
- AO-2008-003-SI-06issued
Who it affects: | Operators of Boeing 747-400 aircraft Status: | Adequately addressed Design of galley floor sealing The floor sealing around the forward galley was not of sufficient extent to prevent liquids from passing through to the under floor area. Issue number: |
- AO-2008-003-SI-07issued
Who it affects: | Operators of Boeing 747-400 aircraft Status: | Adequately addressed Operator’s documented design objectives The aircraft operator’s documented design objectives did not explicitly require the protection of non-structural systems from liquid contact or ingress. Issue number: |
- AO-2008-003-SI-08issued
Who it affects: | Qantas Airways Status: | Adequately addressed Flight crew quick reference handbook The operator’s flight crew quick reference handbook did not include sufficient information for flight crew to manage the emergency. Issue number: |
- AO-2008-003-SI-09issued
Who it affects: | Operators of Boeing 747-400 aircraft Status: | Adequately addressed Fluid protection design guidance The United States Federal Aviation Administration regulations and associated guidance material did not fully address the potential harm to flight safety posed by liquid contamination of electrical system units in transport category aircraft. Issue number: |
- AO-2008-003-SI-10issued
Who it affects: | Manufacturers and operators of transport category aircraft Status: | Safety action pending Battery discharge message priority design The priority level of the battery discharge messages that were provided by the engine indicating and crew alerting system did not accurately reflect the risk presented by the battery discharge status. Issue number: |
- AO-2008-003-SI-11issued
Who it affects: | Operators of Boeing 747-400 aircraft Status: | Partially addressed General details Date: | 07 Jan 2008 | | Investigation status: | Completed | Time: | 0846 UTC | | Investigation type: | Occurrence Investigation | Location ( show map ) : | 25 km NNW of Bangkok International Airport | | | | State: | International | | Occurrence class: | Technical | Release date: | 13 Dec 2010 | | Occurrence category: | Serious Incident | Report status: | Final | | Highest injury level: | None | Aircraft details Aircraft manufacturer: | The Boeing Company | Aircraft model: | 747 | Aircraft registration: | VH-OJM | Serial number: | 25245 | Type of operation: | Air Transport High Capacity | Damage to aircraft: | Nil | Departure point: | London Heathrow, UK Destination: | Bangkok, Thailand