Aero Commander 500
130km SE Mackay Aerodrome, QLD · 2007-09-04·VH-YJR
What happened
ATSB summary, verbatimElectrical System Event, 130 km SE of Mackay Aerodrome, Qld, 4 September 2007, VH-YJR, Rockwell Aero Commander 500-S (Loss of control) Summary During cruise at 9,000 ft, the aircraft encountered severe turbulence and the electrical system failed. The pilot unintentionally lost control of the aircraft when he leaned forward on the control column yoke and used both hands to search in the dark for a torch on the cockpit floor. After recovering the hand-held torch, the pilot was able to light the instrument panel and return the aircraft to the required heading and altitude. When the battery master switch was turned off, the electrical system returned to full operation on alternators. Maintenance personnel found that an internal electrical short in one of the 12 volt batteries had contributed to the electrical failure. After replacement of the faulty battery and completion of satisfactory electrical system checks, the aircraft was returned to service. The pilot of the aircraft now secures his torch to his shirt with a strap to enable him to use both hands to keep control of the aircraft should a similar situation arise. The aircraft operator now secures torches in all its aircraft with the addition of a quick release strap on the torch container.
Findings
the ATSB's findings: contributing factors and other factors that increased risk, verbatimFindings From the evidence available, the following findings are made with respect to the electrical systems failure event involving VH-YJR on 4 September 2007 and should not be read as apportioning blame or liability to any particular organisation or individual. Contributing safety factors • During cruise at night, the aircraft encountered severe turbulence for a short period, displacing the pilot’s and cockpit torches from their stowage positions. • Concurrent with severe turbulence, the aircraft lost electrical power to the cockpit lighting, instruments and radios, due to an electrical short in one of the aircraft’s batteries. • While searching for a torch on the cockpit floor, the pilot leaned forward on the control column, resulting in an unintentional loss of control of the aircraft. Other key findings • The pilot’s action in switching off the battery master switch restored electrical power to the aircraft by isolating the electrical short in one of the aircraft’s batteries. - 4 -
What an account opens
The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.