FlarePath
UK AAIB AAIB-2024-N4698W · UK AAIB · Field investigation

Rockwell Commander 112 TCA

Kinglassie, Fife · 2024-12-23·N4698W

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
1
fatal
0
serious
Fatal
highest injury
Destroyed
damage

What happened

AAIB synopsis, verbatim

Shortly after takeoff from Fife Airport for a brief local flight, closed-circuit television (CCTV) footage from the airport showed that the aircraft departed from controlled flight, possibly entering an incipient spin. Around the same time, CCTV in Kinglassie, one mile south-west of the airport, recorded the sound of an engine apparently misfiring and N4698W is seen to strike rising ground. Post-accident examination of N4698W’s fuel system revealed a significant amount of water contamination throughout the system. N4698W was kept outside at Fife Airport and further examination of the aircraft showed that the right-hand wing filler cap grommet was cracked and this could have allowed rain to enter the fuel system. The AAIB released a Special Bulletin in March 2025 that contained preliminary information on the accident and clarified that it is possible that an entire fuel sample tube of water, drained from the fuel system, can still produce an odour of Aviation gasoline (Avgas) when smelled. The CAA has also undertaken to review ‘Safety sense leaflet number 28: Fuel Handling and Storage’ to incorporate more detailed information for pilots on pre-flight fuel sampling techniques, including techniques to check that a sample is fuel rather than all water and to highlight to pilots the need to check all fuel drain points. Further, one Safety Recommendation is made to Commander Aircraft Corporation to amend the aircraft maintenance manuals to provide specific inspection criteria for the acceptable condition of fuel tank rubber grommet seals.

Conclusion

the AAIB's conclusion, verbatim
Shortly after takeoff, N4698W departed from controlled flight, possibly entering a spin, after the engine began running rough and then lost power completely. The engine’s rough running and loss of power was caused by ingestion of water into the carburettor float bowl, leading to water being fed into the main nozzle. Significant water contamination was present throughout the fuel system downstream of the fuel selector valve and in the left wheel well sump drain. Although the extent of the pilot’s pre-flight inspection could not be determined from the CCTV footage, it was not effective in removing all the water present in the aircraft’s fuel system.

Safety recommendations

1 issuedwhat changed because of this accident
  • AAIB 2026-002issued

    It is recommended that Commander Aircraft Corp. publishes maintenance information that provides specific inspection criteria for the acceptable condition of Rockwell Commander 112/114/115 fuel tank rubber grommet seals.

In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.