FlarePath
UK AAIB AAIB-2022-EIGPN · UK AAIB · Field investigation

ATR 72-212A 600

Belfast City Airport · 2022-09-19·EI-GPN

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
NONE
damage

What happened

AAIB synopsis, verbatim

During the aircraft’s approach to Belfast City Airport, a number of aircraft systems dropped off-line including some necessary for landing. The flight crew, experiencing natural effects of startle and surprise, and without a specified procedure to follow, continued with the approach, restoring systems by turning off the Transformer Rectifier Unit (TRU). The aircraft was operating under an Operations Engineering Bulletin (OEB) which required the TRU to be continually powered. Following the failure of an electrical contactor, this disconnected the DC output from the TRU to the Standby and Emergency bus bars, thereby removing electrical power to several aircraft systems. The aircraft manufacturer has taken safety action to improve the guidance for flight crew in the event of a contactor failure when operating under the OEB. In addition, they have introduced a modification which, when embodied, removes the requirement to operate with the TRU permanently powered. The operator intends to adopt a rule-based method for managing startle, which can help pilots manage workload and maximise their situation awareness before flying an approach.

Conclusion

the AAIB's conclusion, verbatim
The aircraft was operating under EASA Emergency Airworthiness Directive E-AD 2021- 0120-E which had been introduced to de-risk potential problems within the battery master toggle switch and the 1PA contactor. This meant that the TRU was selected on and the 95PA and 96PA contactors were energised throughout all flights. In this case the 95PA contactor failed when the TRU was selected ON and thereby not properly energising, disconnecting the DC output from the TRU to the STBY and EMER BUS bars. This caused a number of vital aircraft systems to drop off-line during the aircraft’s approach to Belfast City Airport. The extreme, unforeseen, and dynamic nature of the failure caused characteristic startle and surprise effects in the flight crew. Without a specified procedure to follow, they continued flying the approach, successfully restoring systems by turning off the TRU which restored electrical power to the affected systems by de-energising failed relay 95PA.
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.