AAIB synopsis, verbatim

Introduction: Annex 13 to the Convention on International Civil Aviation places a responsibility on the State of Occurrence, in this case Belgium as represented by the Air Accident Investigation Unit (AAIU), to commence an investigation. However, the State of Occurrence may, by mutual agreement, delegate the investigation to another State. On 5 June 2019, the AAIU delegated responsibility for this investigation to the State of Registration, as represented by the AAIB. Synopsis: While descending to land at Brussels National Airport, a partial electrical failure occurred resulting in the loss of a number of systems including the electronic and analogue flight instruments on the left side of the cockpit. The pilot declared a MAYDAY and aware that a thunderstorm was approaching the airfield, assessed that the weather reported by Air Traffic Control (ATC) would allow him to continue and land at Brussels. However, visual references were lost at a late stage of the approach when the aircraft entered a heavy rain shower. A go-around was initiated during which the pilots estimated the amount of thrust required; the aircraft initially appeared to be slow to accelerate and establish a positive rate of climb. The aircraft entered an orbit and subsequently landed successfully from a second approach. The electrical failure was caused by a fault in the transfer relay which resulted in the loss of power to a number of electrical buses. The aircraft documentation was unclear as to which aircraft in the fleet were configured to enable the cockpit instruments to be powered from a standby electrical source; this may have affected the pilots understanding of the failure. Safety action has been taken by the operator to provide clarity in the aircraft documentation.

Conclusion

the AAIB's conclusion, verbatim
The electrical failure was caused by a fault in the transfer relay which resulted in the loss of power to a number of electrical buses. Following the electrical failure, the commander’s assessment was that the aircraft was in a stable condition so continued the approach to land at Brussels National Airport. This gave the pilots relatively little time to assess the situation and a number of non-normal checklists actions were not carried out; consequently, the aircraft was incorrectly configured for the approach and landing. At a late stage of the approach the pilots lost visual references and executed a go-around. The aircraft then orbited while the thunderstorms cleared the airfield and the pilots used the time to further analyse the failure. The second approach and landing were uneventful.
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.