FlarePath
UK AAIB AAIB-2019-GFBEJ · UK AAIB · Field investigation

ERJ 190-200 LR (Embraer 195)

Exeter Airport, Devon · 2019-02-28·G-FBEJ

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
1
serious
Serious injury
highest injury
NONE
damage

What happened

AAIB synopsis, verbatim

Summary: As the thrust levers were advanced for takeoff, on an early morning scheduled passenger flight, the flight crew detected an unusual odour and observed smoke entering the cockpit. They then moved the thrust levers to the idle position and applied the parking brake. The cabin crew subsequently reported that there were smoke and fumes in the cabin. Following an assessment of the situation, the commander initiated an emergency evacuation. During the evacuation, passengers who evacuated via the overwing exits reported being unsure of how to get down from the wing to the ground and several re-entered the cabin and exited via one of the escape slides. The smoke and fumes were subsequently attributed to an incorrectly performed engine compressor wash procedure, which was carried out by maintenance personnel the night before the occurrence flight. As a result of the findings of this investigation, the European Union Aviation Safety Agency (EASA) has undertaken two safety actions relating to the certification requirements for overwing emergency exits. The operator has also undertaken several safety actions relating to passenger safety briefings, processes for maintenance planning, engineer training, competency and welfare and monitoring of ground equipment. Four Safety Recommendations are made relating to the certification requirements for overwing exit markings and the height requirement for overwing exits to be equipped with an assisted means of escape.

Conclusion

the AAIB's conclusion, verbatim
A lack of maintenance planning, training and control of resources led to an undesirable situation where a maintenance task was allocated to an engineer who was neither qualified nor competent to complete the task. A key step in the engine drying procedure was only described as ‘recommended’ and the engineer did not complete all the elements of the task. This resulted in residual cleaning solution remaining within the ECS system, causing smoke and fumes within the cabin and cockpit and leading to an emergency evacuation. The engine drying procedure has since been amended to require this step to be carried out. Due to the order in which the emergency evacuation vital actions were performed, the flaps had insufficient time to travel to the selected position. This resulted in an increased drop to the ground for passengers evacuating via the overwing exits, with many reluctant to jump or slide off the wing. Additionally, despite the presence of a marked exit route on the wing with a non-slip surface, many passengers who exited via the overwing exits were uncertain where to go once out of the aircraft. Both of these factors increased the time taken for emergency evacuation to be completed.

Safety recommendations

5 issuedwhat changed because of this accident
  • AAIB 2010-007issued

    It is recommended that the European Aviation Safety Agency review the design, contrast and conspicuity of wing surface markings associated with emergency exits on Public Transport aircraft, with the aim of ensuring that the route to be taken from wing to ground is marked unambiguously. Overwing exit jam The jamming of the right overwing exit door occurred because of insufficient clearance between the top edge of the door trim and the ceiling edge panel. To prevent fouling at this location, adequate clearance must be available in the initial stages of door movement until the door trim panel has passed fully beyond the ceiling panel. In the case of the right overwing exit on G-FBEH, there was effectively no clearance, such that the exit immediately jammed on attempting to open it. The AAIB checks demonstrated that, whilst improving the situation, the 2 mm minimum clearance specified in SB 190-25-0092 was insufficient to prevent the door liner from fouling the ceiling edge panel if the door was lifted firmly as it was unlocked, or if the door was jerked open, as might occur in an emergency. The

  • AAIB 2020-020issued

    It is recommended that the European Union Aviation Safety Agency amends the certification requirements relating to the  design, contrast and  conspicuity  of  overwing  exit escape route markings on commercial air transport  aircraft,  to  ensure  that the route to be taken from wing to ground is immediately apparent to evacuating passengers, in a range of emergency scenarios.

  • AAIB 2020-021issued

    It is recommended that the Federal Aviation Administration amends the certification requirements relating to the design, contrast and  conspicuity  of  overwing  exit escape route markings on commercial air transport  aircraft,  to  ensure  that the route to be taken from wing to ground is immediately apparent to evacuating passengers, in a range of emergency scenarios. Provision of evacuation slides Emergency exits that do not meet the 1.8 m maximum height criteria of FAR/CS 25.810 are not required to be equipped with an evacuation slide. This applies equally to overwing and non-overwing exits. The RAeS paper identified that jumping from heights of up to

  • AAIB 2020-022issued

    It is recommended that the European Union Aviation Safety Agency, re-evaluate and reduce the 1.8 m height criteria in CS 25.810(a) and (d), for the provision of an assisted means of escape at emergency exits, to minimise passenger injuries and reduce egress time during emergency evacuations.

  • AAIB 2020-023issued

    It is recommended that the Federal Aviation Administration, re-evaluate and reduce the 1.8 m height criteria in FAR 25.810(a) and (d), for the provision of an assisted means of escape at emergency exits, to minimise passenger injuries and reduce egress time during emergency evacuations. The operator also updated the content of its briefing to passengers seated in the overwing exits of the E195 as a result of this occurrence. Changes included: simplifying terminology, instructing those passengers of the need to be first out on the wing, informing them of the need to help and direct other passengers, and highlighting that there is no escape slide attached to the overwing exits. Conclusion A lack of maintenance planning, training and control of resources led to an undesirable situation where a maintenance task was allocated to an engineer who was neither qualified nor competent to complete the task. A key step in the engine drying procedure was only described as ‘recommended’ and the engineer did not complete all the elements of the task. This resulted in residual cleaning solution remaining within the ECS system, causing smoke and fumes within the cabin and cockpit and leading to an emergency evacuation. The engine drying procedure has since been amended to require this step

In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.