British Aerospace (BAe) ATP
8 nm west of Milton Keynes · 2018-05-03·SE-MHF
What happened
AAIB synopsis, verbatimSummary: The aircraft experienced a loss of DC electrical power during the cruise whilst operating a cargo flight from East Midlands Airport to Stansted Airport, resulting in the loss of a significant number of flight deck instruments and systems. The crew decided to return to East Midlands Airport where they made a normal landing, following which DC electrical power was restored without crew action. The loss of electrical power was consistent with a failure of the No 1 Transformer Rectifier Unit (TRU) or its contactor, followed by a subsequent failure of the DC essential busbar COUPLE function. Subsequent testing of the aircraft’s electrical system did not identify the cause of either failure. The investigation identified that the aircraft’s FDR was recording intermittently due to corrosion caused by moisture ingress. Two safety recommendations are made, relating to the prevention of moisture entering the FDR on BAe ATP aircraft with the Large Freight Door (LFD) modification and for the replacement of flight recorders using magnetic tape.
Conclusion
the AAIB's conclusion, verbatimThe aircraft experienced two separate, independent failures within the DC electrical power system during a cargo flight from East Midlands Airport to Stansted Airport, resulting in the loss of multiple flight deck instruments, lighting, left engine control and standby flying controls. The crew were able to return to East Midlands Airport where a normal landing was made, following which the DC electrical power was restored. The loss of electrical power experienced during the flight was consistent with a failure of the No 1 TRU or its contactor, followed by a subsequent failure of the DC essential busbar couple function. The cause of both failures, which could not be repeated during subsequent testing, was probably intermittent and transitory so could not determined.
Safety recommendations
2 issuedwhat changed because of this accident- AAIB 2019-001issued
It is recommended that the European Union Aviation Safety Agency (EASA) require BAE SYSTEMS to protect the flight data recorder fitted to those ATP aircraft equipped with large freight doors from the effects of rainwater and other liquids. In response to an ICAO recommendation to discontinue the use of magnetic-tape FDR and CVR technology, EASA required the replacement of all magnetic-tape CVRs with a solid‑state CVR by 1 January 2019. However, although EASA acknowledged that magnetic tape is unreliable, obsolete and ‘have an insufficient recording quality’, they did not require the replacement of magnetic tape FDRs. In addition to the operator of SE-MHF, which has indicated that it intends operating their BAe ATP fleet for several more years, there are also a small number of UK-operated aircraft that are equipped with a magnetic-tape FDR. Discussions with UK based MROs indicate that long-term support for this obsolete technology is declining. However, it may still be several years before aircraft operating in Europe with magnetic-tape FDRs are finally retired from service, or a lack of spares require an operator to install an alternative solid-state FDR.
- AAIB 2019-002issued
It is recommended that the European Union Aviation Safety Agency (EASA) set an end date to prohibit the use of flight data recorders that use magnetic tape as a recording medium, to ensure compliance with ICAO Annex 6 from that date. Conclusion The aircraft experienced two separate, independent failures within the DC electrical power system during a cargo flight from East Midlands Airport to Stansted Airport, resulting in the loss of multiple flight deck instruments, lighting, left engine control and standby flying controls. The crew were able to return to East Midlands Airport where a normal landing was made, following which the DC electrical power was restored. The loss of electrical power experienced during the flight was consistent with a failure of the No 1 TRU or its contactor, followed by a subsequent failure of the DC essential busbar couple function. The cause of both failures, which could not be repeated during subsequent testing, was probably intermittent and transitory so could not determined.