Sikorsky S-61N Sea King
Marchwood, Hampshire · 2018-02-01·G-ATBJ
What happened
AAIB synopsis, verbatimSummary: The helicopter was being transferred from Marchwood, Hampshire, to a maintenance base having been transported, by sea, from the Falkland Islands. As the helicopter took off for a hover check it pitched nose-down. The commander promptly lowered the collective and the helicopter struck the ground on its nose, before coming to rest on its landing gear. The investigation found that the spherical bearing within the swashplate had seized as a result of corrosion, compounded by inactivity during the voyage from the Falkland Islands. The checks prior to the flight did not identify the control restriction. Safety action has been taken by the helicopter manufacturer to highlight the correct pre-flight procedures to follow after prolonged aircraft inactivity, and by the operator to remind flight crews to conduct flight control servo system checks to the maximum extents of control movement. Bulletin correction Prior to publication a correction was issued concerning this report. The online version of the report was corrected on 12 March 2020 and a full description of the correction appeared in the April 2020 Bulletin. Correction: Sikorsky S-61N Sea King, G-ATBJ 04-20
Conclusion
the AAIB's conclusion, verbatimThe cyclic control restriction was found to be as a result of seizure of the spherical bearing with the swashplate. The seizure was determined to be as a result of corrosion build-up within the bearing sockets. Prolonged inactivity during the transportation of the helicopter from the Falkland Islands allowed corrosion to develop sufficiently to cause the bearing to seize. Following the helicopter’s arrival in the UK, Safety Inspection checks detailed in the S-61N Equalized Inspection and Maintenance Program, SA 4047-13 were not carried out; it is likely that the seized swashplate would have been identified if they had. Despite the seizure, the investigation determined that full fore/aft travel of the cyclic control could still be achieved which indicates that this is not a reliable indication that the swashplate is free to move. During pre-flight checks by maintenance engineers and the flight crew, the flight control servo system checks were not completed to the full extremes of travel. With a seized swashplate, the rotor blades changed pitch due to flexing of the guide tube and the blade movement was incorrectly identified as a positive confirmation of control authority. There was no confirmation by external observation of the main rotor and swashplate operation during the limited range pre-flight checks.
What an account opens
The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.