FlarePath
UK AAIB AAIB-2017-GJEDU · UK AAIB · Field investigation

DHC-8-402 Dash 8 Q400

Belfast International Airport · 2017-11-10·G-JEDU

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
Minor injury
highest injury
—
damage

What happened

AAIB synopsis, verbatim

Summary: The aircraft was carrying out the third sector of a four-sector day from Belfast City Airport to Inverness Airport. After takeoff, the landing gear was selected up. Cockpit indications indicated that the main landing gear (MLG) retracted normally but the nose landing gear (NLG) did not. The crew carried out the actions in the relevant abnormal checklists and were unable to lower the NLG. After burning off fuel, the aircraft was diverted to Belfast International Airport where it landed with the NLG retracted. The crew initiated an emergency evacuation. It was determined that a damaged electrical harness on one of the nose landing gear proximity sensors caused an erroneous signal, which resulted in the forward NLG doors starting to close while the NLG was still in transit to the up position. The nose landing gear tyres contacted the forward doors, causing the NLG to rotate off-centre. Although the NLG subsequently retracted, the forward doors remained open and the tyres became jammed in the NLG bay. This prevented the nose landing gear from extending when subsequently commanded. The damage to the harness resulted from a cyclically-driven fatigue failure mechanism, which occurred because the harness had been secured with a non-flexible cable tie which restricted it from flexing during normal nose landing gear operation. The aircraft manufacturer has taken action to clarify nose landing gear proximity sensor harness routing and attachment instructions in the Aircraft Maintenance Manual, and has published inspection requirements. Following the accident, the operator carried out an inspection of the nose landing gear proximity sensor harness routing on its Dash 8 Q400 fleet and undertook rectification of any anomalies noted. The aircraft and landing gear manufacturers are also working to identify a more flexible harness design; this activity had been initiated before the accident to G-JEDU.

Conclusion

the AAIB's conclusion, verbatim
The investigation concluded that mechanical damage within the electrical harness of the primary ‘nose gear lock’ proximity sensor caused an intermittent and erroneous sensor state change during landing gear retraction. The measured inductance value associated with the sensor state change was not sufficiently high for the sensor to be flagged as faulted, and the erroneous state change was therefore considered valid. This had the effect of interrupting the NLG retraction sequence by causing the forward NLG doors to close prematurely while the NLG was still retracting, such that the tyres came into contact with the doors. When the NLG finally retracted, the tyres became jammed in the NLG bay, preventing it from extending when subsequently commanded. The flight crew followed the appropriate procedures for dealing with the incident, which led to the safe landing and evacuation. Prior to this accident, the failure mode of an erroneous sensor state change below the threshold at which the sensor would declare itself faulted, had not previously been identified.
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.