FlarePath
UK AAIB AAIB-2017-GGSGS · UK AAIB · Field investigation

HPH Glasflugel 304 eS

Parham Airfield, West Sussex · 2017-08-10·G-GSGS

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
—
damage

What happened

AAIB synopsis, verbatim

Summary: During a normal touchdown following an uneventful flight, the glider’s forward FES lithium polymer battery ignited due to an electrical arcing event. The pilot was unaware that the glider was on fire and the battery continued to burn, generating smoke and fumes which entered the cockpit during the latter stages of the landing roll. The pilot was not injured and the fire was extinguished using foam retardant, although the glider’s fuselage battery box and surrounding structure were extensively damaged by the fire. A comprehensive investigation of the failed battery did not identify the cause of the electrical arcing event. The AAIB published a Special Bulletin, S3/2017, in September 2017 that contained three Safety Recommendations relating to the provision of fire warning systems in FES-equipped sailplanes. As a result of this investigation the sailplane manufacturer and FES system manufacturer have implemented a number of safety actions intended to prevent recurrence, or to mitigate the effects of a battery fire.

Conclusion

the AAIB's conclusion, verbatim
During a normal touchdown following an uneventful flight, the glider’s forward FES lithium polymer battery ignited due to an electrical arcing event. The pilot was unaware that the glider was on fire and the battery continued to burn, generating smoke and fumes which entered the cockpit during the latter stages of the landing roll. The pilot was not injured and the fire was extinguished using foam retardant, although the glider’s fuselage battery box and surrounding structure was extensively fire-damaged. A detailed examination of the forward FES battery did not determine the cause of the battery fire. The G-GSGS battery fire was the second of three such FES battery fires that have occurred to date. A survey of other FES batteries from the in-service fleet revealed the presence of metallic debris in a significant proportion of those batteries examined. Vibration testing conducted by the AAIB showed that the presence of metallic debris can cause battery cell pouch fretting although this was not sufficiently severe to cause an internal short circuit and electrical arcing.

Safety recommendations

3 issuedwhat changed because of this accident
  • AAIB 2017-018issued

    It is recommended that the European Aviation Safety Agency (EASA) requires that all powered sailplanes, operating under either an EASA Restricted Type Certificate, or an EASA Permit to Fly, and fitted with a Front Electric Sustainer (FES) system, are equipped with a warning system to alert the pilot to the presence of a fire or other hazardous condition in the FES battery compartment.

  • AAIB 2017-019issued

    It is recommended that Alisport Srl modifies the Silent 2 Electro microlight to incorporate a warning system to alert the pilot to the presence of a fire or other hazardous condition in the Front Electric Sustainer (FES) battery compartment.

  • AAIB 2017-020issued

    It is recommended that Albastar d.o.o. modifies the AS13.5m Front Electric Sustainer (FES) microlight to incorporate a warning system to alert the pilot to the presence of a fire or other hazardous condition in the FES battery compartment. In response to these Safety Recommendations, the affected FES-equipped sailplanes have been modified with an independent warning system to alert the pilot to the presence of a fire in the FES battery compartment. Battery and sailplane improvements The HPH 304 eS sailplane manufacturer has replaced the composite battery compartment forward bulkhead with a stainless steel bulkhead to improve the fire-resistance of the bulkhead in the event of a battery compartment fire. The internal surfaces of the battery compartment are now painted in an intumescent fireproof paint finish. The existing fleet of FES batteries was withdrawn from use and is currently being refurbished to a new design standard, to which new production batteries

In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.