Airbus A330-323
London Heathrow Airport · 2016-06-26·N276AY
What happened
AAIB synopsis, verbatimSummary: The cabin filled with smoke whilst the aircraft was on stand after boarding. The cabin crew were unsuccessful in making contact with the commander, and one of the flight attendants (FAs) initiated a passenger evacuation. Several passengers exited using the emergency slides from the two aft doors, but most left using the jetbridge at exit 2L. Passengers opened the two emergency exits situated immediately aft of the wings (exit 3L and exit 3R). Exit 3L had not been armed, so the slides did not deploy and the passengers did not use the exit. Exit 3R was armed and opened by a passenger and the slide deployed, but this exit was not used either. The commander attempted to halt the evacuation, (because he believed he had isolated the source of the smoke) which caused some confusion until the FAs encouraged all remaining passengers to exit via the jetbridge. Air Traffic Control (ATC) observed the incident and alerted the emergency services, which reached the scene quickly. Three passengers and several FAs received treatment for the effects of smoke inhalation and one passenger suffered a minor leg injury while using an escape slide. The source of the smoke was traced to a failure of the Auxiliary Power Unit (APU) load compressor carbon seal that allowed hot oil to enter and pyrolyse in the bleed air supply. Metallic debris in the shared oil system compromised the load compressor bearing, leading to the failure of the load compressor carbon seal. The APU manufacturer has taken action to address this type of event, and the relevant section of the Master Minimum Equipment List (MMEL) has been reviewed and amended. Six Safety Recommendations are made in the areas of interphone design, passenger briefings and the co-ordination of pilot and cabin crew training. A further two Safety Recommendations are made concerning modification to enhance automatic APU shut-down protection in the event of lubrication system contamination.
Conclusion
the AAIB's conclusion, verbatimSmoke entered the cabin after the APU load compressor oil seal became compromised, allowing hot oil to enter and pyrolyse in the bleed air supply to the cabin. Examination of the APU after the event revealed considerable metallic debris in its shared oil system. This debris eventually caused the load compressor carbon seal to fail, allowing hot oil to enter the bleed air supply to the cabin and causing smoke in the cabin. The initiating source of the debris could not be identified positively due to the distribution of debris throughout the oil system. Modifications exist to mitigate these conditions and two Safety Recommendations have been made that an optional SB, to add enhanced APU automatic shut-down protection for lubrication system contamination, be mandated.
Safety recommendations
8 issuedwhat changed because of this accident- AAIB 2017-022issued
It is recommended that the Federal Aviation Administration mandate Service Bulletin GTCP331-49-7936 to add a system that shuts down the APU automatically if there is contamination of the lubricating oil.
- AAIB 2017-023issued
It is recommended that the European Aviation Safety Agency mandate Service Bulletin GTCP331-49-7936 to add a system that shuts down the APU automatically if there is contamination of the lubricating oil. This event surprised the crew and developed quickly. The pilots were pre-occupied with resolving an unrelated system defect and the flight deck environment was complicated by the presence of an engineer and the GOC. In the cabin, some FAs had found passenger boarding more pressured than normal and preparations were being made for a manual safety briefing when the smoke appeared. First appearance of smoke Several FAs attempted to contact the commander, in accordance with the operator’s guidance but using the normal interphone call function. None of the pilots noticed the small amber lights on the ACPs or the single buzzer tone which announced a cabin interphone
- AAIB 2017-024issued
It is recommended that the Federal Aviation Administration regulate the operation of interphone handsets, including during emergency communications, so that it is standardised irrespective of aircraft type. And:
- AAIB 2017-025issued
It is recommended that the European Aviation Safety Agency regulate the operation of interphone handsets, including during emergency communications, so that it is standardised irrespective of aircraft type. When smoke became apparent in the flight deck, the flight crew responded quickly by taking action they considered appropriate but they did not call the FAs to establish the situation in the cabin. The smoke lavatory smoke checklist requires this to be done and, although an emergency interphone call is not specified, this offers the best means of conferring with all the FAs. The lack of such immediate liaison with the FAs indicates that training to respond to smoke events while on the ground could be improved. The aircraft operator has reported the action it intends to take to address this (see Aircraft operator’s response in the Safety action section). Initiation of evacuation When the E-FA received no response to her interphone call, she decided the situation was life-threatening and made a PA to initiate an evacuation. The alternative ‘Emergency Deplaning’ procedure was not mentioned in guidance to flight crew. An appropriate drill has now been introduced (see Aircraft operator’s response in the Safety action section). The
- AAIB 2017-026issued
It is recommended that the Federal Aviation Administration reconsider the requirements for briefings given to passengers seated at exits, to ensure they offer appropriate guidance on exiting the aircraft rapidly in an emergency without implying undue responsibility for opening the exits. A review of previous similar events suggests that this scenario is not unique and indicates it is desirable for trained crew members to be available to operate floor-level emergency exits whenever an aircraft is on the ground with passengers on-board. The practice of
- AAIB 2017-027issued
It is recommended that the Federal Aviation Administration require cabin crew on aircraft that are parked, and with passengers on-board who are neither boarding nor deplaning, to be evenly distributed throughout the cabin and in the vicinity of floor-level exits in order to provide the most effective assistance in the event of an emergency. And:
- AAIB 2017-028issued
It is recommended that the European Aviation Safety Agency require cabin crew on aircraft that are parked and with passengers on-board to be evenly distributed throughout the cabin and in the vicinity of floor-level exits, in order to provide the most effective assistance in the event of an emergency. Evacuation from 4L and 4R Having been unsuccessful contacting the flight crew by interphone, the four FAs in the aft galley area assessed that the situation merited an emergency evacuation. The lavatory smoke alarm was sounding in the cabin but the C-FA misidentified this as the secondary evacuation signal. The sounds of the two alarms are different and AIP provides a further indication, so this misinterpretation suggests inadequate training or knowledge of the systems. However, even if the alarm had been correctly identified, it is likely that the dense and noxious smoke was sufficient for the FAs in the aft galley to initiate evacuation, with or without a PA instruction being heard. The FAs reported that they worked in a well-coordinated manner to arm the doors and begin an orderly evacuation, with the first passengers seen using the 4R slide one minute after smoke was first emitted from the APU exhaust.
- AAIB 2017-029issued
It is recommended that the Federal Aviation Administration require that flight and cabin crew participate in joint training to enhance their co-ordination when dealing with emergencies.