AAIB synopsis, verbatim

Summary: During the en route climb, the flight crew noticed smoke and fumes in the cockpit and donned their oxygen masks. Shortly after, the ECAM AVIONICS SMOKE caption was displayed and the aircraft diverted to Newcastle Airport. During the descent, the smoke appeared to dissipate after the crew carried out the Quick Reference Handbook (QRH) avionics smoke drill. The aircraft landed without further incident. The source of the smoke and fumes was traced to the cockpit additional electrical supply static inverter, which had overheated. This was the third failure to have occurred on the operator’s fleet of Airbus A320 aircraft since August 2014. The operator was not aware that the aircraft manufacturer had issued a technical publication in March 2016 that identified the cause of the problem, and that the supplier had issued a Vendor Service Bulletin in October 2016 that recommended the replacement of the capacitor involved in the failure mode. A batch of 2,058 units was affected. The failed static inverter on G-EZWX was one of this batch. The investigation also identified an undocumented feature of the interphone emergency call function related to communication re-establishment after a handset reset; awareness of this feature could improve communication management between the cockpit and cabin crew.

Conclusion

the AAIB's conclusion, verbatim
Static inverter failure The source of the smoke and fumes was traced to the cockpit additional electrical supply static inverter, which had overheated. The manufacturer of the static inverter isolated the fault to a component, capacitor C306, which had not received an individual quality screening prior to fitment. A batch of 2,058 static inverters were affected. The incident on G-EZWX was the eleventh failure reported to the aircraft manufacturer which had resulted in the release of smoke and fumes into the cockpit. Of the eleven failures, at least seven had resulted in diversions. The operator was not aware until after the incident that the manufacturer of the static inverter had published VSB 1830-25-37, nor that the aircraft manufacturer had previously communicated the problem with the static inverters in TFU 24.00.00.114. This was because the operator was not registered to receive notifications of VSB’s from the manufacturer of the inverter and, like another large UK operator, did not routinely review TFUs. Following a decision in September 2016, the aircraft manufacturer subsequently issued OIT 999.0096/16 to all operators on 15 December 2016 to “broaden awareness” that the reason for the failure of the static inverter had been identified and VSB 1830-25-37 had been published to address this. Both the aircraft manufacturer and the operator intend further safety action, in addition to that which has already been taken. Emergency interphone communications Initial communications between the CM and co-pilot using the emergency interphone system failed to be established, as the co-pilot either inadvertently omitted to set up his ACP to transmit on the cabin interphone channel or did not select the transmit button. The CM was unable to hear the co-pilot and hung up his handset, which disconnected it from the emergency call. Communication was subsequently established with the CM about three minutes later when the co-pilot selected the forward interphone call option. The investigation identified that neither information nor training was provided to crew on how to re-establish communications to the cockpit in the event that a cabin handset became disconnected from an emergency interphone call initiated from the cockpit. Whilst an emergency call is in progress, it is not possible to initiate a call to the cockpit from a handset that has been disconnected. However, by selecting the emer call button on the disconnected handset’s keypad, the handset is reconnected to the emergency call, allowing communications with the cockpit and other cabin crew who are also on the call. The CM was not aware of this feature, but had he been, communications may have been established more quickly. The emergency interphone system is infrequently
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.