Airbus A319-111
Belfast Aldergrove Airport · 2015-06-25·G-EZAA
What happened
AAIB synopsis, verbatimSummary: The flight crew planned to perform a takeoff from Runway 25 using Intersection Bravo at Belfast Aldergrove Airport. The initial performance figures, calculated using the Electronic Flight Bag (EFB), were computed for a wet runway; this produced a full power thrust setting. Just before pushback, as the runway was dry, the crew elected to change the runway state on the EFB from wet to dry to see if this would produce a reduced engine thrust setting, which it did. During the takeoff roll, as the end of the runway became visible at about 115 kt, the commander felt that a rejected takeoff would not provide sufficient stopping distance and thus became ‘Go’ minded. The aircraft subsequently got airborne with about 200 m of runway remaining. After departure, analysis by the crew revealed that an incorrect runway was used to calculate the dry runway performance figures, resulting in erroneous figures being generated. The reason for this could not be confirmed but subsequent investigations revealed that in one scenario, an involuntary runway change could occur on the EFB. This anomaly was not known by the operator or manufacturer at the time of the event and is likely to have been the reason for the incorrect runway selection. These figures were not identified as erroneous and were subsequently used for takeoff.
Conclusion
the AAIB's conclusion, verbatimThe incident was caused by the use of incorrect takeoff performance data. The data was most likely calculated using Runway 07 instead of Runway 25B. The most likely reason for using Runway 07 was an involuntary runway selection by an anomaly within the EFB software which went undetected by the crew. They did not conduct an independent check of the selected runway when their recollection was of changing only the runway condition. Operators have been informed of the anomaly and the EFB software will be corrected in future standards. The commander recognised the limited stopping distance available just before V1 but the potential seriousness of the event is highlighted by the theoretical result of a runway overrun at 75 kt if the takeoff had been rejected at that stage. A number of international, European and national initiatives are underway to consider and address the safety risks posed by using erroneous takeoff performance parameters.
What an account opens
The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.