Boeing 737-36Q

East Midlands Airport · 2014-09-03·G-GDFT

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
Minor injury
highest injury
—
damage

What happened

AAIB synopsis, verbatim

Summary: The aircraft landed at East Midlands Airport following an electrical failure in flight, which the crew diagnosed as a failure of the battery busbar . As the aircraft taxied towards its parking stand, an acrid smoke haze appeared within the cabin and flight deck and an emergency evacuation was carried out. Although the aircraft was successfully evacuated, cabin communication difficulties were encountered, due to the failure of the PA system and a fault with a loud hailer unit. The battery bus failure was caused by one or more loose R1 relay terminals, leading to a break in electrical continuity. The acrid smoke in the cabin and cockpit was a direct result of the relay failure. The loss of the air cycle machine (ACM) cooling fans caused dust and oil residue to burn off the hot metal duct surfaces in the air conditioning system and the resulting fumes entered the cabin, prompting the evacuation.

Conclusion

the AAIB's conclusion, verbatim
The electrical difficulties experienced in this aircraft were as a direct result of the loss of continuity between the R1 relay terminals. This was due to one of its terminals loosening in its insulated mounting over an indeterminate period of time and moving away from the contactor, thus breaking continuity. It is possible that this was caused by an overtightened terminal nut weakening the terminal and insulator soldered joint whilst at the same time being under a degree of tension or side load from the heavy gauge electrical cables.
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.