What happened

AAIB synopsis, verbatim

Pioneer 400, G-TLOY Summary: During a test flight for the initial issue of a Permit to Fly, the pilot reported a loss of pitch control authority during a go-around from low speed. On the subsequent approach the pilot delayed lowering the landing gear to ensure he could land on the airstrip, but it was not fully extended by the time the aircraft touched down and the gear collapsed during the landing roll. Prior to the flight 50% of the length of the elevator trim tab Gurney flap had been removed to correct a perceived problem of limited forward elevator authority during cruise, and post-accident inspection revealed that the elevator cables had low tension. After repair the aircraft was test flown by the LAA’s Chief Test Pilot, who considered the design was acceptable without further change.

Conclusion

the AAIB's conclusion, verbatim
Discussion The final inspection before first flight did not identify any anomalies with the aircraft and previous flights by the accident pilot and another familiar with the type were without incident. Prior to this flight 50% of the length of the fixed Gurney flap had been removed after the pilot had noted an apparent limited forward elevator authority during cruise. The post-accident inspection by an independent inspector found the tension of the elevator cables was low, but because it is possible that they were damaged during a post-accident attempt at disassembly, their tension at the time of the accident is not certain, although no anomalies had been noted on the previous flights. The reduction of the size of the Gurney flap and possible low tension in the elevator control cables both have the potential to alter the feel and range of the pitch control system. A temporary control restriction in the cockpit also could not be discounted. Subsequent test flying of the aircraft after repair and with the Gurney flap returned to its standard configuration showed that the aircraft performed as expected and the LAA consider the design is acceptable without change.
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.