What happened

AAIB synopsis, verbatim

Socata TB10 Tobago, G-RIAM Summary: The occupants were on a local flight at 2,500 ft when they noticed smoke entering the cabin around the base of the windscreen. The aircraft diverted into Coventry Airport, with the intensity of the smoke increasing and affecting visibility, and made a safe landing. The smoke was caused by an internal failure in the alternator regulator and one Safety Recommendation is made to the EASA, to review this installation.

Conclusion

the AAIB's conclusion, verbatim
Discussion This event occurred following the failure of the alternator regulator, which generated sufficient heat to cause charring in an adjacent layer of cabin insulation. The resulting smoke presented a genuine emergency for the inexperienced pilot, who was fortunately able to hand control of the aircraft to his front seat passenger, an experienced professional pilot. The latter’s experience may have contributed to his decisive handling of the emergency, which included expediting the landing at Coventry after the smoke increased in intensity. But for his intervention, the outcome may have been more serious. In order to limit the extent of any fire, it is important to perform the items listed in the Emergency Checklist. Although this document was not referred to during the incident, it was apparent that many of the items were actioned. Comparison with the Cessna 172 incident suggests that location of the regulator, aft of the firewall, was a significant factor in the G-RIAM event. The regulator in the Cessna failed in a way that similarly generated heat (although this is not necessarily an inevitable consequence of a regulator failure) but its location in the engine compartment did not directly lead to the in‑flight fire; that was due to the injudicious resetting of the alternator circuit breaker. ELECTRICAL FIRE IN FLIGHT If Fire is in Engine Compartment Master Switch.........................................................Off Cabin Air................................................. Fire Shut Off LAND AS SOON AS POSSIBLE If Fire Is In Cabin Master Switch.........................................................Off Alternator Switch....................................................Off All Electrical Switches (Except Magnetos)............Off Cabin Air...................................................Fire Cut Off Fire Extinguisher.................................................... Use 8/2012

Safety recommendations

1 issuedwhat changed because of this accident
  • AAIB 2012-022issued

    It is recommended that the European Aviation Safety Agency review the alternator regulator installation of the SOCATA TB series of single-engine aircraft, with a view to reducing the risk to the operation of the aircraft as a result of smoke/fire arising from a failure of this component.