What happened
AAIB synopsis, verbatimBreezer B600, G-OLSA Summary: Shortly after takeoff the engine stopped due to a loss of fuel pressure and the pilot made a forced landing which resulted in a heavy touchdown. The engine stoppage was probably caused by a fuel restriction when a placard blocked the fuel tank outlet. The fuel tank outlet was not fitted with a strainer or filter as none was required by the regulations for a ‘Light Sport Aeroplane’ (LSA). The aircraft manufacturer has taken safety action to install a fuel strainer at the fuel tank outlet of all new aircraft and is offering the same modification for retrofit. Two Safety Recommendations are made.
Conclusion
the AAIB's conclusion, verbatimAnalysis The engine stoppage was probably caused by a fuel restriction when the placard from the fuel sender blocked the fuel tank outlet. The aircraft manufacturer was not able to establish why the placard had not been removed from the fuel sender prior to installation, but it has introduced further checks to ensure that the placard is removed in future. Although not required by CS-LSA or ASTM F2245, the manufacturer has taken safety action to install a fuel strainer at the fuel tank outlet of all new aircraft and is offering the same modification for retrofit. UK microlight aircraft designed to BCAR Section S and EASA-certified Very Light Aircraft (VLAs) are required to have a fuel strainer fitted at the fuel tank outlet. Without a fuel strainer a foreign object in the tank, such as a piece of paper or a leaf, could completely restrict the fuel flow and result in engine stoppage. Therefore the following two Safety Recommendations are made.
Safety recommendations
2 issuedwhat changed because of this accident- AAIB 2012-020issued
It is recommended that the European Aviation Safety Agency (EASA) amend ‘Certification Specifications for Light Sport Aeroplanes’ (CS-LSA) to require the installation of a strainer at the fuel tank outlet, to reduce the risk of foreign objects in the fuel tank restricting the fuel supply.
- AAIB 2012-021issued
It is recommended that ASTM International amend the ‘Standard Specification for Design and Performance of a Light Sport Airplane’ (ASTM F2245) to require the installation of a strainer at the fuel tank outlet, to reduce the risk of foreign objects in the fuel tank restricting the fuel supply.