FlarePath
UK AAIB AAIB-2011-GMANH · UK AAIB · Field investigation

BAe.ATP

Cardiff Airport · 2011-04-09·G-MANH

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
—
damage

What happened

AAIB synopsis, verbatim

BAe.ATP, G-MANH Summary: During an otherwise normal landing at Cardiff, a failure in the right landing gear freed the axle to oscillate about a vertical axis, leading to severe damage and deflation of both tyres. The original failure was the result of the corrosion induced weakening of a threaded attachment. Consequent overload fracture of another component appears to have taken place before the Cardiff landing. The landing gear manufacturer is introducing a new Service Bulletin to address the deterioration of the corroded and failed area in service and amending the build procedure to obviate the possibility of surface damage during component assembly creating an origin for a corrosion process. A further problem noted during the fleet inspection following the original event has been addressed in the final Service Bulletin.

Conclusion

the AAIB's conclusion, verbatim
Analysis The condition of the internal thread forms in the castellated nut and the external threads on the pin were consistent with corrosion having removed material from the flanks of the thread forms in the nut and on the pin. This combination had apparently reduced the depth of mutual engagement to the point where the threaded joint was unable to carry its design axial load. The destruction of the locking bolt, the presence of internal axial grooves created within the nut (apparently by the fractured end faces of the locking bolt) and damage to the crests of the engaging thread forms, were all features consistent with axial separation of the castellated nut from the pin. It was clear that axial loading had failed the corrosion weakened thread engagement. This had initially transferred the end load, applied via the lugs to the castellated nut, from their design support medium - the threaded joint between the pin and castellated nut - to the locking bolt (normally intended purely to prevent rotation of the castellated nut on the pin). The nature of the visible damage to the ends of the surviving mid section of the locking bolt (being approximately conical / spherical in shape) was consistent with a sequence of discrete double shear loads being applied with different angular orientations by the castellated nut, after failure of its thread engagement, on the pin. This in turn was consistent with the bolt rotating in its bore in the pin between a series of shear load applications. The failure of the weakened joint between the castellated nut and apex pin was thus the result of a sequence of loads applied to the nut through the torque links. These are presumed to have been caused by oscillating angular movement of the axle in a horizontal plane. Such repeat loading and failure was consistent with the effects of shimmy applied to a weakened nut/pin joint also having reduced angular restraint on motion of the axle in the horizontal plane. Once complete failure of the lock bolt had occurred, the nut was no
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.