Bombardier DHC-8-402 Dash 8
Approximately 25 nm south-west of Carlisle at FL240 · 2011-07-21·G-ECOF
What happened
AAIB synopsis, verbatimBombardier DHC-8-402 Dash 8, G-ECOF Summary: In the cruise at FL240, the aircraft generated a spurious smoke warning from the forward baggage compartment. The crew assumed the warning was valid and carried out checklist actions designed to tackle fire or smoke from an unknown source. This resulted in power being removed from the co-pilot’s flight displays, the autopilot, the Instrument Landing System (ILS), the transponder, the CVR and FDR, and caused the aircraft to begin to depressurise. The aircraft landed safely at Edinburgh following a Surveillance Radar Approach (SRA), vacated the runway and the passengers were evacuated onto a taxiway. The investigation indicated that the spurious warning was probably caused by an intermittent short-circuit in a smoke detector connector as a result of moisture ingress.
Conclusion
the AAIB's conclusion, verbatimAnalysis Engineering analysis The aircraft suffered a false and intermittent forward baggage compartment smoke warning. No faults with the aircraft wiring system were found and, after removal of the forward smoke detector and the fire control amplifier, there were no further reports of false smoke warnings on the aircraft. It is probable, therefore, that either the smoke detector or the amplifier generated the false warning. The amplifier could generate a false smoke warning but only when exposed to high levels of moisture not representative of normal operating conditions. It is therefore more likely that the spurious warning was caused by a short circuit at the smoke detector connector between pin B and the connector shell. The evidence of corrosion in this area indicated that moisture had been present, and sufficient moisture would have provided a conductive path from the pin to the shell. Grounding pin B triggers a self-test, which would have given the flight crew indications of a smoke warning and would have armed the fire extinguishers. The type of connector used on the smoke detector is normally resistant to moisture ingress but the lack of blanking pins in the unused sockets meant that moisture in the air could reach the pins. The fact that the corrosion was primarily present at pin B, the pin at the lowest point, was consistent with the theory that moisture had collected there.
What an account opens
The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.