FlarePath
UK AAIB AAIB-2011-GBVXF · UK AAIB · Field investigation

Cameron O-120 hot air balloon

Midsomer Norton, Somerset · 2011-01-01·G-BVXF

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
2
fatal
0
serious
Fatal
highest injury
Destroyed
damage

What happened

AAIB synopsis, verbatim

Cameron O-120 hot air balloon, G-BVXF

Conclusion

the AAIB's conclusion, verbatim
Analysis There were several items that require analysis to determine the causal or contributory factors in this accident. Radar information A key piece of evidence was the height profile from the radar, Figure 5. Comparing the altitude profiles of the accident flight with another Gold Badge flight (for which the descent was initiated by not using the burners and not venting) strongly suggests either the envelope of G-BVXF was vented or there was a significant leakage of hot air due to an envelope failure. The high rate of ascent, which reduced only slightly prior to the apogee at 21,500 ft, is indicative of an intact balloon envelope at that stage; it is likely that the CAA approval to FL210, already passed, could have led the pilot to decide to initiate a more rapid descent than he had originally planned. Supplementary oxygen system Another key piece of evidence was that the main valve, and the regulator, on the oxygen cylinder were found in the closed position. It is possible that these had been opened at high altitude but were closed during the descent. However, given that both valves were found closed, that the valves were located in a rucksack and hence not readily accessible, and that the pilot and passenger were probably focussed on trying to re-inflate the envelope during the rapid descent, the closing of the valves during this descent is unlikely. There was evidence from the communications with Bristol ATC that both occupants were conscious and not in distress just prior to the descent. The radio call suggested that the descent was being initiated, which implies that a pull on the parachute valve line was planned, rather than simply turning off the burners and allowing time to transition to a cold descent. If the supplementary oxygen was not being used during the flight then the occupants would have been subjected to conditions where hypoxia would have had the potential to affect their decision making, their performance and, ultimately, the ability of the pilot to control the aircraft safely. Envelope inspection The inspection of the envelope did not reveal any abnormality that could have contributed to the accident. The tear in the parachute valve, which probably occurred after the balloon was ‘streamered’, was in itself too small to cause the envelope to deflate rapidly and would not have significantly affected flight performance. The temperature indicator revealed that the balloon had been hot, but not excessively so, and hence any heat-induced failure of the envelope is unlikely. There was significant fire damage to the envelope, which could readily be
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.