Beagle B121 Series 1 Pup
Panshanger Aerodrome, Hertfordshire · 2011-04-22·G-AXPM
What happened
AAIB synopsis, verbatimBeagle B121 Series 1 Pup, G-AXPM Summary: Following a 50-hour check, the aircraft’s ignition switch was left in the RIGHT position, with no key in the switch, due to the use of an incorrect key. During the next pre-flight inspection the pilot perceived that the ignition switch was in the OFF position. As he turned the propeller by hand, as required by the aircraft’s EXTERNAL INSPECTION checklist, the engine started and ran at full power. The aircraft broke free of its tie-downs, struck a parked aircraft and crashed into an earth embankment. Safety action has been taken concerning the content of the aircraft’s flight manual and service manual checklists.
Conclusion
the AAIB's conclusion, verbatimAnalysis The accident occurred because the propeller was rotated whilst the right magneto was live, despite no key being present in the ignition switch. When the pilot visually checked the ignition switch by looking into the cockpit from the left cabin door, he confirmed that no key was in the switch but parallax error made it difficult to differentiate between the RIGHT and OFF switch positions. In addition, the lack of a key in the switch reinforced the pilot’s perception that the switch was in the OFF position, as this is what he had become accustomed to expect during seven year’s ownership of the aircraft. The aircraft’s EXTERNAL INSPECTION checklist required that the pilot configured the aircraft in a state in which the engine would start, and run at full power, if for any reason the propeller was rotated whilst ignition system was live. In this respect, the checklist design was a dormant failure. It required a single breach of the only available defence – reliance on the ignition system being OFF – to create the dangerous situation where the engine would start, and run at full power, after being turned over by hand. The cause of the ignition being left in a live condition in the accident was the use of an incorrect key by the maintenance engineer sustituting for the correct key. However, a similar hazardous condition could have arisen in the case of a broken magneto primary lead, or an internal electrical fault in a magneto. It is likely that the lack of previous similar accidents is partially due to the use of commercially available checklists that do not contain pre-flight inspection tasks that place the engine in a configuration to start, when rotated by hand, in the event of a live ignition system.
What an account opens
The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.