de Havilland Canada DHC-6 300 Twin Otter
London Gatwick Airport · 2010-02-24·C-FAKB
What happened
AAIB synopsis, verbatimDe Havilland Canada DHC-6 300 Twin Otter, C-FAKB Summary: During a ferry flight from Calgary, Canada to the Maldives, an electrical fire started in the power distribution and generator control box located in the roof of the passenger cabin. The crew isolated the electrical systems and successfully diverted to London Gatwick Airport. The source of the fire was traced to the left generator reverse current relay, which was found to have a different part number to the relays authorised for use on the DHC-6 series of aircraft. Five Safety Recommendations were made.
Conclusion
the AAIB's conclusion, verbatimAnalysis Cause of fire The damage to the aircraft indicates that the electrical fire started in the left RCR and the fire, and associated heat damage, did not spread outside the power distribution and generator control box.
Safety recommendations
5 issuedwhat changed because of this accident- AAIB 2010-083issued
It is recommended that Transport Canada reviews the design and efficacy of the heat shields fitted around the Reverse Current Relays on De Havilland DHC-6 aircraft that were introduced as a result of Airworthiness Directive CF-77-08. Reverse current relays The investigation established that the left RCR that failed during the accident flight and the right relay removed prior to the start of the ferry flight were both identified as A-700A relays, which is an obsolete part that has not been approved for use on the De Havilland
- AAIB 2010-084issued
It is recommended that Transport Canada takes appropriate action to ensure that only approved Reverse Current Relays are fitted to De Havilland DHC-6 aircraft. A review of previous occurrences of overheating of the RCRs indicates that failures generally occurred due to arcing, and welding, of the main contacts and was most likely to occur on the relays rated at 300 amps (A-700AP and A-700AAP). While modification 6/1585 introduced relay A-701D, rated at 400 amps with an improved contact design, there was no requirement to replace the existing 300 amps relays providing their contacts were examined every 1,200 hours. Given that most of the occurrences of overheating appear to have occurred with the relays rated at 300 amps, the following Safety Recommendation is made to Transport Canada:
- AAIB 2010-085issued
It is recommended that Transport Canada require the replacement of existing Reverse Current Relays (part number A-700AP and A-700AAP) fitted to De Havilland DHC-6 aircraft with relays of a higher current rating and improved design of the electrical contacts. While the Authorised Release Certificates recorded that both A-700A relays had been overhauled, the maintenance organisation responsible confirmed that they had not undergone a full overhaul, but instead had been electrically tested in accordance with what they believed was the OEM manual. The normal practice was that if the relay failed any part of the test then the relevant component would be replaced and the relay retested. This approach was entirely consistent with the DHC-6 Inspection Requirements Manual, which only required the relays to be bench tested every
- AAIB 2010-086issued
It is recommended that Transport Canada reviews the maintenance requirements for the Reverse Current Relay fitted to De Havilland DHC-6 aircraft and considers requiring the relay to be overhauled on a regular basis. The Authorized Release Certificate for RCRs serial numbers 33284 and 33283 stated that the relays had been ‘overhauled I.A.W Hartman Manual A-700A’.
- AAIB 2010-087issued
It is recommended that Transport Canada conduct an audit of Condor Aircraft Accessories Inc’s internal processes to ensure that work recorded on the Authorized Release Certificate accurately reflects the work carried out on the component.