UK AAIB AAIB-2010-5NMJI · UK AAIB · Field investigation

Boeing 737-76N

Southend Airport, Essex · 2010-11-21·5N-MJI

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
NONE
damage

What happened

AAIB synopsis, verbatim

Boeing 737-76N, 5N-MJI Summary: The crew had programmed the aircraft’s Flight Management Computer (FMC) for a maximum thrust takeoff from Runway 24 at SouthendAirport. As the aircraft taxied out, ATC changed the runway in use to Runway 06. The FMC was re-programmed but an incorrect ‘assumed’ temperature was entered, resulting in too great a thrust reduction for the runway length available. Although the aircraft became airborne before the end of the runway, had the takeoff been rejected just before V1 there would have been insufficient runway remaining within which to stop.

Conclusion

the AAIB's conclusion, verbatim
Discussion The crew considered that they were under time pressure to depart as soon as possible, due to the delay caused by the commander’s transport problems. Despite this, they had correctly carried out the flight planning and performance calculations for the departure from Runway 24. Neither crew member was familiar with the airport, so the commander, who was taxiing the aircraft and carrying out the radio communication, was concentrating on ensuring he complied with the taxi clearance. When the runway change was given, the co-pilot carried out the re-programming of the FMC. Although he called out the data he was entering, neither crew member noticed that an incorrect ‘assumed’ temperature had been entered, as opposed to the maximum thrust setting. By commencing the takeoff roll from the displaced threshold, the runway TORA was effectively reduced by 600 ft. The commander, recognising the slower than expected acceleration, called for maximum thrust but, although he thought it had been applied, the recorded engine parameters did not support this. Both pilots were qualified aircraft commanders and there appears to have been an element of mutual confidence in the other pilot’s ability to perform his task correctly. The adherence to SOPs, when the FMC was programmed for a departure from Runway 24, broke down when it was re-programmed for a departure from Runway 06. Whilst the aircraft became airborne and achieved the screen height by the end of the runway, with both engines operating, the manufacturer considered that, had an engine failed at or close to V1, the aircraft may not have stopped, if the takeoff had been rejected, or become airborne by the end of the runway if the takeoff had been continued. In view of the safety actions taken by the operator after this incident, no Safety Recommendation is considered necessary.
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.