UK AAIB AAIB-2009-GJEDI · UK AAIB · Field investigation
DHC-8-402 Dash 8
London Gatwick Airport · 2009-12-21·G-JEDI
Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
—
damage
What happened
AAIB synopsis, verbatimDHC-8-402 Dash 8, G-JEDI Summary: During departure from London Gatwick, the aircraft suffered a failure of its AC electrical system. A PAN was declared and the aircraft returned to Gatwick for an uneventful landing. Examination revealed wiring damage in the trailing edge area of the left centre wing that was due to chafing from the head of a blind rivet in a loom support bracket. The aircraft manufacturer has since issued a modification to replace the blind rivets with solid rivets and to inspect the wiring for damage.
Conclusion
the AAIB's conclusion, verbatimAnalysis Engineering issues The examination of the wiring loom indicated that the failure resulted from chafing by the head of the blind rivet that secures the loom support bracket to the aircraft structure. The action of inserting a blind rivet causes a shear lip on the inner stem. The loom sits upon the loom support bracket and the tie wrap is inserted around the loom and over the head of the rivet and its stem. Over time the relative movement of the wiring loom to the fixed support bracket caused localised chafing, firstly, of the tie strap and then of the wiring loom itself. The stem of the rivet is cadmium plated and particles of cadmium were found in the tie strap and wiring recovered from the area of the fire. There are no other items in the affected area that are cadmium plated and therefore the particles can only have come from the blind rivet stem. The chafing reached an extent where the insulation of one of the wires was compromised and a short, with associated arcing, occurred between the wire and rivet stem, which would have had a ground potential. This arcing would have led to localised heating and damage to the other wire’s insulation and eventual arcing between wires as well as the structure. The first indication that the chafing had reached the extent that shorting was taking place was the indication to the flight crew of the failures of the AC electrical system. It is likely that the GCU detected over current due to shorting in the left generator supply. The GCU would then have automatically switched over contactor K1 so that the Right AC generator was supplying the Left AC bus. However, the affected wiring loom also contained wiring that was supplied from the left AC bus, and this therefore led to faults being detected by the right GCU and the subsequent shutting down of the Right AC generator. With both generators now deactivated, there was no longer an AC supply to the left and right AC Buses and the systems supplied by them would also have failed as a result of the loss of power. It is likely that the left generator drive shaft was still attached during and following the flight. However, when the engineers powered up the AC electrical system on the ground, high currents within the system, from the potential paralleling of the frequency wild generators due to the wiring loom damage, would have caused the generator to electro-magnetically lock and the drive shaft to shear as designed.
In FlarePath for this case
What an account opens
AnalyseThe Analyst and the S.I. Assistantone timeline across the recorders, precedent accidents, answers from the 1 documents with the page they came fromKeepCasebook and briefsnotes pinned to the evidence, an investigation brief, a read-only link for your team
The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.