AAIB synopsis, verbatim

Dornier 328-100, D-CIRT Summary: The aircraft had not been in regular use for almost 2 years and was being repositioned from Dundee to a maintenance facility in Germany, in preparation for sale. The crew experienced a variety of system malfunctions during the takeoff and initial climb, followed by a loss of oil pressure on the left engine. The crew declared an emergency with Leuchars ATC and were receiving radar vectors to return to Dundee when the oil pressure on the right engine also began to fluctuate. The crew advised ATC that they were experiencing problems with both engines and manoeuvred the aircraft to land at RAF Leuchars, an airfield with which they were not familiar. After landing there was no external evidence of an oil leak, but the left and right engines had lost approximately seven and four quarts of oil respectively. The subsequent engineering investigation revealed that in both engines the air-switching valve had seized due to the presence of corrosion, which allowed the oil system to become over pressurised and caused oil to be vented overboard. One Safety Recommendation is made.

Conclusion

the AAIB's conclusion, verbatim
The cause of this serious incident was the failure of both engine air-switching valves to operate normally. This resulted in the over-pressurisation of the engine oil cavities and the purging of oil overboard through the engine vent system. The presence of corrosion on the pistons, piston rings and the inner bore of the valves, caused as a result of the prolonged storage of the aircraft, prevented the valves from operating normally. The crew were faced with a series of malfunctions resulting in their decision to land at the nearest suitable airfield. However, these intentions were not communicated effectively to ATC and it was the decisive action of the Leuchars controllers which prevented an escalation of an already difficult situation.

Safety recommendations

1 issuedwhat changed because of this accident
  • AAIB 2010-094issued

    It is recommended that Pratt and Whitney Canada amend the maintenance requirements for the PW100 series of engines, to ensure the continued serviceability of the air-switching valve on engines installed on aircraft in storage. The engine manufacturer has subsequently confirmed that they will review the de-preservation requirements for these engines and amend them as necessary. Transport Canada has confirmed that they will monitor this activity. Conclusion The cause of this serious incident was the failure of both engine air-switching valves to operate normally. This resulted in the over-pressurisation of the engine oil cavities and the purging of oil overboard through the engine vent system. The presence of corrosion on the pistons, piston rings and the inner bore of the valves, caused as a result of the prolonged storage of the aircraft, prevented the valves from operating normally. The crew were faced with a series of malfunctions resulting in their decision to land at the nearest suitable airfield. However, these intentions were not communicated effectively to ATC and it was the decisive action of the Leuchars controllers which prevented an escalation of an already difficult situation.