FlarePath
UK AAIB AAIB-2008-PHKZB · UK AAIB · Field investigation

Fokker F.28 Mark 0070

Manchester Airport · 2008-09-29·PH-KZB

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
Minor injury
highest injury
—
damage

What happened

AAIB synopsis, verbatim

Fokker F.28 Mark 0070, PH-KZB Summary: The aircraft was taxied onto Stand 214C (centre) using the right engine with the left engine shut down and the APU running. As soon as the right engine was shut down, there was a strong smell of electrical burning and smoke began to accumulate on the flight deck. Following a brief discussion with the Cabin Service Supervisor, the aircraft was evacuated. An engineering investigation identified that the emergency inverter cooling fan capacitor, was completely burnt out. This had released smoke and fumes into the flight deck area.

Conclusion

the AAIB's conclusion, verbatim
Analysis Operational matters With both main engines shut down and the passengers standing retrieving their belongings, the situation was outside the circumstances which would normally exist in an emergency evacuation as set out in the abnormal checklist. There was no time to prepare the passengers and crew to carry out an evacuation. The commander, seeing the smoke developing, wanted the passengers off the aircraft as his first priority and firmly instructed the CSS to do this. Her initial attempt to get the passengers to leave the aircraft by saying, ‘get off the aircraft now. Hurry, evacuate the aircraft,’ produced little response. Given the strength of the commander’s instruction and the urgency of the situation, the CSS raised the assertiveness in her voice and carried out the evacuation drill. The evacuation proceeded rapidly whilst the flight crew alerted ATC, attempted to identify where the smoke was coming from and ultimately shut down the aircraft. Whilst he had not specifically ordered an ‘evacuation’, the commander fully supported the decision and actions of the CSS. The movement of the passengers off the wing would have been made safer by lowering the flaps. Without the hydraulic system to power the flap actuators the electrical system would have been the only method of achieving this. Using this system would have either meant delaying the use of the overwing exits whilst the flaps were lowered or having the flaps travelling as passengers were on or possibly under them. Both of these options carried associated additional risk. The airport Emergency Planning Committee has addressed the concerns of the Airport Fire Service, Officer in Charge regarding the entry of unauthorised persons into a risk area. Engineering During the incident, a cooling fan power supply capacitor, located adjacent to the fan within the emergency inverter unit, overheated and generated a significant quantity of smoke. The cooling fan continued to operate, drawing the smoke out of the inverter casing and through the hole in the dividing wall between the inverter equipment bay and the area behind the upper circuit breaker panel. As this space was completely enclosed, it then entered the flight deck via the gaps around the panel. The co‑pilot opened his sliding window to allow the smoke to clear, but this most likely set up a circulation cell
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.