FlarePath
UK AAIB AAIB-2008-N101DW · UK AAIB · Field investigation

Piper PA-32R-300

Runway 24, Southend Airport, Essex · 2008-07-04·N101DW

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
—
damage

What happened

AAIB synopsis, verbatim

Piper PA-32R-300, N101DW Summary: The aircraft suffered a failure of its electric power generation system when five miles offshore on a flight from Panshanger to Oostend. This resulted in the loss of all electrical services. The aircraft diverted to Southend airport where it landed with the landing gear retracted.

Conclusion

the AAIB's conclusion, verbatim
The pilot considered the accident was caused by a failure of the aircraft’s electrical system. Whilst this was certainly a contributory factor, the alternative system for lowering the landing gear was demonstrated to be serviceable during the recovery operation. It is likely, therefore, that the system would have successfully lowered the landing gear in-flight, had it been selected. Figure 3 Main alternator feed cable and alternator connecting lug
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.