Raytheon 390 Premier I
En route Copenhagen, Denmark to Farnborough, UK · 2008-08-07·G-FRYL
What happened
AAIB synopsis, verbatimRaytheon 390 Premier I, G-FRYL Summary: During descent the crew reported experiencing the loss of airspeed information followed by the loss of all three electronic flight instrument system (EFIS) displays. The investigation concluded that the loss of air data information was due to a blockage in the right pitot system caused by moisture ingress which subsequently froze. However, despite exhaustive testing, it was not possible to determine the cause of the loss of all three EFIS displays. One Safety Recommendation is made.
Conclusion
the AAIB's conclusion, verbatimAnalysis Loss of airspeed information The sequence of events during this incident began with the IAS comparator warning, indicating a mismatch in IAS sensed by the two ADCS. The loss of standby airspeed information, for which the only source is the right pitot/static system, indicated a problem with the right pitot system. Subsequent testing on the aircraft reproduced the events which occurred during the incident. With a blockage introduced in the right pitot line, and the static pressure increased, with no change in pitot pressure, the difference between the static and the pitot pressure, ie the dynamic pressure and thus the indicated airspeed, reduced. The indications on the flight deck were a reduction in indicated airspeed data from ADC2 and the standby ASI. As the static pressure increased to a value greater than the blocked pitot pressure, ADC2 and the standby airspeed indicator would have sensed a negative airspeed. The ADC would identify this as an invalid input and would ‘fail’ at this point, displaying the three red flags on the EFIS. The faults recorded in the MDC during the test replicated those recorded during the incident. The return of valid air data information as the aircraft descended supports the theory that the blockage was caused by ice, which then melted as the outside air temperature rose. Subsequent investigations found no faults within either of the ADCs or the right pitot/static probe. There have been previous incidents on the Premier 1 of moisture ingress leading to loss of air data information, and temperatures in the right avionics bay can be sufficiently low to allow any moisture present to freeze. This operator has reported that the operation of the pitot and static drains is not always sufficient to clear moisture, and that the systems can require purging to ensure that all moisture is removed. This was the case following this incident, where no water was found in the pitot and static lines by operating the drains; however, some water was found by purging.
Safety recommendations
1 issuedwhat changed because of this accident- AAIB 2009-109issued
It is recommended that the Federal Aviation Administration should require Hawker Beechcraft Corporation to review and modify, if necessary, the design of the pitot and static drainage on the Premier 1 aircraft in order that its pitot/static systems cannot become blocked as a result of trapped moisture. Loss of EFIS displays During the testing it was not possible to recreate that part of the sequence of events in which the pilots reported the blanking of all three displays. At 1803 hrs the Autopilot and Yaw damper disengaged. Analysis of the fault codes recorded by the MDC indicates that this was probably due to the difference in the airspeeds sensed by the two ADCs. The failure of ADC2 at 1805 hrs, which was supplying air data to both PFDs by that time, would have resulted in the three red flags being displayed on both PFDs and the loss of all air data information. The Mode S data indicated that there was no loss of altitude information, which should have continued to be displayed on the PFDs. The co-pilot recalled that, initially, the compass rose presentation and artificial horizon remained visible on both PFDs. Use of the reversionary display control would have resulted in the momentary blanking of PFD1 and
What an account opens
The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.