Embraer ERJ 190-200 LR (Embraer 195)
40 nm NW of Wallesey, en route from Manchester to Belfast City · 2008-08-01·G-FBEH
What happened
AAIB synopsis, verbatimEmbraer ERJ 190-200 LR (Embraer 195), G-FBEH Summary: The aircraft was operating a scheduled passenger transport flight with the No 2 air conditioning pack inoperative, as permitted by the Minimum Equipment List (MEL). Whilst en route, a failure of the No 1 Air Cycle Machine (ACM) occurred, releasing smoke and fumes into the aircraft. A MAYDAY was declared and an expeditious diversion was carried out. After donning oxygen masks the pilots had great difficulty communicating with each other, ATC and cabin crew, because of technical problems with the masks. During the emergency evacuation the right overwing emergency exit door became jammed and unusable. Passengers who evacuated via the left overwing exit were unaware of how to get from the wing down to the ground. Two Safety Recommendations are made as a result of this investigation.
Conclusion
the AAIB's conclusion, verbatimAnalysis Crew decision making The commander’s decision to divert to the Isle of Man was based on his concern that there might have been a fire on the aircraft. The sulphurous smell experienced by both pilots was something that they had never encountered on an aircraft before, but one which they uniquely associated with burning. Having made the decision to divert, the commander had limited time in which to achieve a straight-in approach and landing. This task was made more difficult by the communication difficulties experienced once the pilots had donned their oxygen masks. Consequently, the commander omitted to inform the SCCM that they were diverting and it also led to his decision not to attempt to speak to the passengers over the PA. The fluctuating intensity of the smell meant that the commander did not decide to perform an emergency evacuation until late in the flight. His intentions were not communicated to the cabin crew and passengers and they were therefore surprised by the command to evacuate. However, despite the unexpected nature of the order to evacuate, this did not delay its commencement. Door 1R & 1L configurations & passenger flow issues None of the passengers evacuated the aircraft via D1R. This, it is considered, was influenced by the staggered layout of the front two emergency exits. In addition, there was only one crew member situated in this part of the cabin to direct and assist passengers during the evacuation and he was standing next to D1L. Passengers would have therefore had to find and use D1R at their own initiative. Overwing escape route markings It is apparent from this incident that the issue of ambiguous overwing escape route markings that resulted in AAIB Safety Recommendation 2002-42 still exists. It is therefore appropriate that this matter is re-examined. As responsibility for aircraft certification now lies with the EASA, the previous Safety Recommendation is therefore re-issued as follows:
Safety recommendations
2 issuedwhat changed because of this accident- AAIB 2010-007issued
It is recommended that the European Aviation Safety Agency review the design, contrast and conspicuity of wing surface markings associated with emergency exits on Public Transport aircraft, with the aim of ensuring that the route to be taken from wing to ground is marked unambiguously. Overwing exit jam The jamming of the right overwing exit door occurred because of insufficient clearance between the top edge of the door trim and the ceiling edge panel. To prevent fouling at this location, adequate clearance must be available in the initial stages of door movement until the door trim panel has passed fully beyond the ceiling panel. In the case of the right overwing exit on G-FBEH, there was effectively no clearance, such that the exit immediately jammed on attempting to open it. The AAIB checks demonstrated that, whilst improving the situation, the 2 mm minimum clearance specified in SB 190-25-0092 was insufficient to prevent the door liner from fouling the ceiling edge panel if the door was lifted firmly as it was unlocked, or if the door was jerked open, as might occur in an emergency. The
- AAIB 2010-008issued
It is recommended that Embraer modify the overwing emergency exits on Embraer 195 aircraft, to eliminate the possibility of the exit door jamming due to interference between the door trim panel and the ceiling edge panel. ACM turbine failures Examinations of the failed turbine wheels from G-FBEH showed that they had failed due to fatigue cracking originating in a location of high stresses associated with a known blade resonance condition. A new Stage 2 turbine housing was under development to address the problem. The failure of the Stage 2 turbine on the No 1 ACM occurred after only four days out of the 10 days of single‑pack operation permitted by the MEL. This suggests that the turbine speed had encroached into the resonance range during this period. It is possible that other units could be similarly vulnerable during single‑pack operation. However, the aircraft manufacturer stated that this event was the only known case of the failure of an ACM Stage 2 turbine during single-pack operation on the Embraer 190/195 fleet. They also reported that the reliability of the air conditioning pack had been significantly improved through various modifications and maintenance actions, significantly reducing the probability of Stage 2 turbine failures. Therefore no