FlarePath
UK AAIB AAIB-2008-GBYKU · UK AAIB · Field investigation

BFC Challenger II

On approach to Runway 25 at Otherton Airfield, Staffordshire · 2008-07-22·G-BYKU

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
—
damage

What happened

AAIB synopsis, verbatim

BFC Challenger II, G-BYKU Summary: The propeller and hub assembly detached from the aircraft at a late stage on the approach. The pilot was able to continue with a glide approach and landed safely on the runway. The investigation established that thread locking compound had not been applied to the propeller hub mounting bolts, allowing them to vibrate loose. This resulted in fatigue cracks developing in the bolts, causing them to fail.

Conclusion

the AAIB's conclusion, verbatim
Comment From the available evidence, it is probable that thread locking compound was not applied to the six propeller hub mounting bolts, which subsequently vibrated loose. This led to the initiation of fatigue cracks in the bolts which led to the bolts finally failing in ductile overload during the accident flight. Although not an issue in this accident, the investigation identified a number of issues concerning the use of thread locking compounds on aircraft. In order to prevent fatigue failure of the hub mounting bolts, it is necessary to apply a sufficient clamping force to prevent movement between the propeller hub and top pulley. This is achieved by applying the aircraft manufacturer’s specified torque of 15 lbf ft to the hub mounting bolts. As the breakaway torque for Loctite 271 is 22 lbf ft, any subsequent torque check of these bolts would only confirm the integrity of the adhesive contact between the threads and would not prove that the clamping force between the components had been correctly applied. There is also a risk, particularly if the thread locking compound has not had sufficient time to reach its full strength, that any subsequent torque check of the hub mounting bolts may break the adhesive contact, thereby rendering the locking compound ineffective. It is for these reasons that torque checks should not be carried out on assemblies where a thread locking compound has been used. As a result of these findings, and given the discrepancies between instructions issued by the aircraft manufacturer and the PFA (now the LAA), the Airworthiness Information Leaflets for the inspection
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.