What happened

AAIB synopsis, verbatim

Eurocopter EC155 B1, G-ISSV Summary: The aircraft was being refuelled on the ramp with the rotors running when a localised fire broke out in the area of the external connector for the electric hoist, on the upper right side of the fuselage. The fire went out as soon as electrical power was removed on shutting down the engines. The investigation established that the fire was caused by the 28 volt DC electric hoist power supply shorting to the body of the hoist’s fixed electrical connector and earthing through the carbon fibre composite fairing on which the connector is mounted. The short was probably caused by moisture ingress into the connector due to a damaged seal. A contributory factor was that the connector is always live whenever the electrical system is powered. Three safety recommendations are made to the aircraft manufacturer.

Conclusion

the AAIB's conclusion, verbatim
The evidence suggests that the fire in the hoist connector was caused by the 28 volt DC hoist motor power supply shorting to the body of the connector and earthing through the carbon fibre composite fairing. The most likely cause of the short was moisture ingress into the connector, resulting from a damaged environmental seal. A contributory factor was that the power supply to the connector is always live whenever the aircraft generators are on line.

Safety recommendations

3 issuedwhat changed because of this accident
  • AAIB 2007-072issued

    It is recommended that Eurocopter modify the method of sealing the hoist connector ‘24 DELTA’ on EC155 aircraft, to ensure that it is effective in preventing moisture ingress into the connector. In this and the previous hoist fire incident, the fixed connector was installed with the power and earth contacts facing downwards. This orientation of the contacts could increase the likelihood of an electrical short if moisture is present within the connector. To reduce the likelihood of shorting, the following Safety Recommendation is made:

  • AAIB 2007-073issued

    It is recommended that Eurocopter determine the most appropriate orientation for mounting the EC155 hoist fixed connector to minimise its susceptibility to shorting from moisture ingress. Hoist motor power supply The electrical supply to the hoist’s fixed connector is, by design, live whenever the aircraft generators are on line. There is therefore no way for the flight crew to isolate the supply to the connector, other than taking the generators off line, or shutting down the engines, neither of which is acceptable in flight. If a hoist connector fire were to occur in flight, and the fire were to spread, the safety of the aircraft and its crew would be at risk. To provide this means of disconnection, rather than relying on a high-current electrical fuse, the following Safety Recommendation is made:

  • AAIB 2007-074issued

    , Eurocopter has stated that, although, it agrees with the principle of this recommendation, it would be difficult to comply with it because of the problems inherent in installing such a line contactor. As noted above, Eurocopter proposes, instead, to install a grounding strap between the external connector and ‘ground’, to ensure that the fuse in the power supply line would blow in the case of a short circuit in the connector. This step would clearly reduce the possibility of a short circuit in the connector causing damage but would not necessarily protect against a short circuit in the power supply line.