FlarePath
UK AAIB AAIB-2007-GFIZU · UK AAIB · Field investigation

Lockheed L188C

London Stansted Airport · 2007-03-19·G-FIZU

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
—
damage

What happened

AAIB synopsis, verbatim

Lockheed L188C, G-FIZU Summary: Immediately after takeoff on a night flight from Stansted to Edinburgh the flight crew experienced control difficulties and fluctuation of the RPM and power on all four engines. As the aircraft climbed towards 3,000 feet QNH the number 2 engine was observed to be running down. The crew shut the engine down, declared a PAN and prepared to return to Stansted. The remaining three engines continued to suffer from fluctuating parameters throughout the remainder of the flight until, when on final approach with landing flap selected, both the number 1 and number 3 engines appeared to run down. The aircraft landed using the remaining engine. The investigation revealed that the incident was the result of a failure of the propeller synchrophaser.

Conclusion

the AAIB's conclusion, verbatim
The cause of the incident was a failure within the power supply circuit board in the propeller synchrophaser unit. This caused significant power and rpm fluctuations on all four engines giving the flight crew difficulty in handling the aircraft. The No 2 engine exceeded its maximum governed speed which resulted in the fuel flow to the engine being cut back by its governor; this led the crew to believe that the engine had begun to run down and they shut that engine down. The remaining engines continued to fluctuate and, on final approach, the No 1 and 3 engines also appeared to run down, probably due to fuel being cut back after overspeeding.
In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.