FlarePath
UK AAIB AAIB-2007-GEZIU · UK AAIB · Field investigation

Airbus A319-111

En route to from Barcelona to Liverpool · 2007-02-06·G-EZIU

Open this case in FlarePathSign inThe record below is free to read. An account opens the recorders, the photographs and the Analyst.
0
fatal
0
serious
No injury
highest injury
NONE
damage

What happened

AAIB synopsis, verbatim

Airbus A319-111, G-EZIU Summary: During a scheduled passenger flight from Barcelona to Liverpool, numerous caution messages and accompanying aural tones were generated, some of which occurred repeatedly for the remainder of the flight. Although the flight crew were unable to resolve the problem, they concluded that the messages were most probably spurious. A MAYDAY was declared and the aircraft was diverted to London Stansted, where it landed safely. No faults were confirmed that could have accounted for these symptoms, but an intermittent fault in one of the Display Management Computers was considered to be the most likely cause.

Conclusion

the AAIB's conclusion, verbatim
Analysis Reported symptoms Despite extensive on and off-aircraft testing, no hard faults were found that could account for the symptoms experienced during the incident flight. The DMC 1 BITE data showed that, during this and the previous incident, data received by the PUMA 0 was judged to be invalid. The information on the captain’s displays that used the PUMA 0 interface would have become unavailable; this was indicated by the crew report that the captain’s PFD and ND indications were similar to those that appear during inertial reference system alignment. The engine parameters are processed by both the PUMA 0 and PUMA 1 in parallel within the DMC, so the engine parameter information on ECAM remained unaffected during this incident as the

Safety recommendations

1 issuedwhat changed because of this accident
  • AAIB 2009-058issued

    It is recommended that Airbus either amend the Quick Reference Handbook of Airbus aircraft with switchable EIS DMC selections, or introduce a memory drill, to emphasise that EIS DMC switching may be an appropriate response to abnormal display unit operation, even if no ‘INVALID DATA’ message is displayed. Conclusion Despite extensive testing, the equipment manufacturer was unable to reproduce a hard fault that could account

In FlarePath for this case

What an account opens

The Explorer account is free and reads the whole record. The recorders, the Analyst and the Casebook are the paid plans.